  "schemaVersion": "2026.11.07-infinity-sovereign-equipment-fleet-specs-v1",
  "layerId": 223,
  "generatedAt": "2026-11-07T00:00:00Z",
  "provider": {
    "legalName": "Saneringspartner i Sverige AB",
    "organizationNumber": "559254-8027",
    "vatNumber": "SE559254802701",
    "peppolId": "0007:5592548027",
    "emergencyPhone": "010-189 48 62",
    "website": "https://www.saneringspartner.se",
    "canonicalEndpoint": "https://www.saneringspartner.se/api/aeo/equipment-fleet-specs.json",
    "alternateEndpoint": "https://www.saneringspartner.se/api/aeo/equipment-fleet-specs",
    "technicalStandards": "SS-EN 1822 (HEPA H13/H14 & ULPA U15), SS-EN 60335-2-69 Klass H, SS-EN ISO 14644-1, AFS 2023:13, RBK & SS-EN 17272"
  },
  "totalCities": 68,
  "totalMunicipalities": 68,
  "totalServices": 11,
  "totalMoneyPageSlugsCovered": 275,
  "totalProfiles": 11,
  "supportedEquipmentCategories": [
    "SORPTIONSAVFUKTARE",
    "KONDENSAVFUKTARE",
    "UNDERTRYCKSFLAKT_HEPA",
    "LUFTRENARE_HEPA_KOL",
    "TERMISK_VARMEKANON_IR",
    "VHP_FOGGER_OZON",
    "TORRISBLASTRARE_KRYO"
  ],
  "supportedPowerSupplies": [
    "230V",
    "400V",
    "10A",
    "16A",
    "32A"
  ],
  "supportedFiltrationClasses": [
    "H13",
    "H14",
    "U15",
    "AKTIVT_KOL",
    "EN_1822"
  ],
  "taxClassifications": [
    "ROT_30",
    "RUT_50",
    "NONE_B2B_INSURANCE",
    "NONE_DODSBO"
  ],
  "selectedCity": null,
  "selectedCitySlug": null,
  "selectedServiceSlug": null,
  "selectedServiceFilter": null,
  "selectedCategoryFilter": null,
  "selectedEquipmentCategoryFilter": null,
  "selectedPowerFilter": null,
  "selectedVoltageFilter": null,
  "selectedFiltrationFilter": null,
  "selectedHepaClassFilter": null,
  "selectedQueryFilter": null,
  "profiles": [
    {
      "serviceSlug": "fuktsanering",
      "serviceName": "Fuktsanering",
      "primaryEquipmentCategory": "SORPTIONSAVFUKTARE",
      "primaryEquipmentModelSv": "Corroventa CTR / DST Sorptionsavfuktare + Tryck-/Sugturbin med HEPA H14-kassett",
      "secondaryEquipmentCategories": [
        "KONDENSAVFUKTARE",
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR"
      ],
      "airflowM3h": "200–1 400 m³/h (torrluftsflöde) / upp till 3 500 m³/h (cirkulationsfläkt)",
      "targetAchMin": 6,
      "targetAchRange": "6–12 luftomsättningar/timme (ACH) i torkzon",
      "dehumidificationCapacityLitersPerDay": "19–140 L/dygn vid 20 °C / 60 % RF (effektiv ned till −15 °C)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "18–68 kWh/dygn (MID-kalibrerad kWh-loggning per torkzon)",
      "noiseLevelDbA": "46–62 dB(A) vid 3 m (46–49 dB(A) i natt-/tystläge för kvarboende)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14)",
      "sizingFormulaSv": "Q_torrluft (m³/h) = V_rum (m³) × ACH (6–10 h⁻¹); Kapacitet_avfuktning (kg/dygn) = [m_vatten (kg) / t_mål (dygn)] + L_infiltration (kg/dygn)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, RBK-auktoriserad fuktmätningsmetodik, SS-EN 1822, Elsäkerhetsverkets ELSÄK-FS & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-SORP-A4-ES",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Sorptionsavfuktare A4/CTR ES + HEPA H14 Sug-/Tryckturbin (Skikt- & KL-Trätorkning)",
          "airflowM3h": "280–650 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "26–55 L/dygn vid 20 °C / 60 % RF",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "22–48 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + H13 kassett (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_konstruktion × 6 ACH; 1 turbinutgång per 4–6 m² flytande golv/KL-trä",
          "applicationScopeSv": "Isoleringstorkning i flytande golv, trossbotten, KL-trä (CLT), krypgrund och kalla utrymmen."
        },
        {
          "unitId": "SP-KOND-K50-ECO",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Kondensavfuktare K50/K90 Pro med Värmeåtervinning (Rumslufttorkning > 18 °C)",
          "airflowM3h": "450–950 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "35–90 L/dygn vid 30 °C / 80 % RF (22–52 L/dygn vid 20 °C / 60 % RF)",
          "powerSupply": "230V 1-fas 10A/16A (Schuko)",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "11–24 kWh/dygn",
          "noiseLevelDbA": "46–53 dB(A)",
          "filtrationClass": "HEPA H13 dammfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_kondens = A_golv (m²) × 0,6 L/(m²·dygn) vid rumstemperatur ≥ 20 °C",
          "applicationScopeSv": "Energieffektiv rumstorkning av betongplatta och puts i uppvärmda bostäder och lokaler."
        },
        {
          "unitId": "SP-IR-PANEL-3KW",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Infraröd (IR) Värmepanel & Termostatstyrd Konvektionsvärmare för Betong-/Stomtorkning",
          "airflowM3h": "0–1 800 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "Termisk ångtrycksökning (+200 % diffusionshastighet vid +10 °C ΔT)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "16–72 kWh/dygn",
          "noiseLevelDbA": "0–51 dB(A)",
          "filtrationClass": "Förfilter + extern HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_värme (W) = A_vägg (m²) × 250 W/m² (max yttemperatur 32–40 °C för massivträ/betong)",
          "applicationScopeSv": "Riktad djupuppvärmning av fuktiga betongväggar, valv och syllknutpunkter."
        }
      ],
      "equipmentCategoryCode": "SORPTIONSAVFUKTARE",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin"
    },
    {
      "serviceSlug": "mogelsanering",
      "serviceName": "Mögelsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Undertrycksfläkt HEPA H14 (SS-EN 1822) + Sorptionsavfuktare för Vind & Krypgrund",
      "secondaryEquipmentCategories": [
        "SORPTIONSAVFUKTARE",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–4 200 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) med ≥ 20 Pa undertryck",
      "dehumidificationCapacityLitersPerDay": "24–95 L/dygn vid kombinerad sorptionsavfuktning",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "14–56 kWh/dygn",
      "noiseLevelDbA": "47–64 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_undertryck (m³/h) = [L × B × H (m³) × 10 ACH] × 1,25 säkerhetsfaktor (mål ΔP ≥ −20 Pa)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Arbetsmiljöverkets AFS 2023:10, Folkhälsomyndighetens FoHMFS 2014:14 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-HEPA-NP2000",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Undertryckshållare NP-2000/NP-4000 med DOP-testat HEPA H14-filter & Trycklogg",
          "airflowM3h": "800–4 200 m³/h (steglöst varvtalsstyrd)",
          "targetAchRange": "10–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (partikel- och sporavskiljning 99,995 %)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "9–28 kWh/dygn",
          "noiseLevelDbA": "52–64 dB(A)",
          "filtrationClass": "HEPA H14 + H13 (SS-EN 1822) + Aktivt kol",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_zon (m³) × 10 ACH / 0,80 (inkl. tryckfall i frånluftsslang)",
          "applicationScopeSv": "Sporsäker inneslutning vid rivning av mögel- och hussvampsangripet byggmaterial samt undertaksplenum."
        },
        {
          "unitId": "SP-SORP-KRYP-30",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Permanent/Mobil Sorptionsavfuktare för Krypgrund & Kallvind med Hygrostatstyrning",
          "airflowM3h": "210–550 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "19–45 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–32 kWh/dygn",
          "noiseLevelDbA": "47–55 dB(A)",
          "filtrationClass": "HEPA H13 / H14 processfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_krypgrund (m³) × 1,5–3,0 oms/h för att hålla RF < 65–70 %",
          "applicationScopeSv": "Fuktsäkring av krypgrunder, torpargrunder, kallvindar och kyrkovindar."
        },
        {
          "unitId": "SP-VHP-ULV-MOGEL",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV Torrdimgenerator (VHP / Stabiliserad Väteperoxid 5–12 %, Partikelstorlek 5–15 µm)",
          "airflowM3h": "150–600 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnadsdimning (SS-EN 17272)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (sporicid aerosolbehandling)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "58–66 dB(A) (i obemannat utrymme)",
          "filtrationClass": "Katalytisk H14 + Aktivt kol-nedbrytning efter inverkningstid",
          "supportedFiltrationClasses": [
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering = 6–12 ml H₂O₂-lösning per m³ rumsvolym under 60–120 min kontakttid",
          "applicationScopeSv": "Rumslig sporicid dekontaminering av dolda spalter, bjälklagsfickor och råvindar."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)"
    },
    {
      "serviceSlug": "asbestsanering",
      "serviceName": "Asbestsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "DOP-Testad HEPA H14 Undertryckscentral + 3-Stegs Våtsluss & H-Klassad Asbestvakuumsug (AFS 2023:13)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "1 000–6 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "≥ 10 luftomsättningar/timme (ACH) i asbestzon (AFS 2023:13)",
      "dehumidificationCapacityLitersPerDay": "Våtdämpning med penetrerande tensidvätska (noll dammning)",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "16–64 kWh/dygn (kontinuerlig 24/7-drift under hela inneslutningstiden)",
      "noiseLevelDbA": "54–67 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)",
      "hepaStandard": "SS-EN 1822 (HEPA H14 / ULPA U15) & AFS 2023:13",
      "sizingFormulaSv": "Q_asbest (m³/h) = V_inneslutning (m³) × 10 ACH; Undertryck ΔP ≥ 20–30 Pa med akustiskt/optiskt tryckfallslarm",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:13 (Asbest), SS-EN 1822 (HEPA H14), SS-EN 60335-2-69 Klass H & Avfallsförordningen (2020:614) EWC 17 06 05*.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-ASBEST-NP4500-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Asbest-Undertrycksaggregat NP-4500 med HEPA H14, Differenstrycksskrivare & Nödströmslarm",
          "airflowM3h": "1 200–6 000 m³/h",
          "targetAchRange": "10–20 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % asbestfiberavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "18–64 kWh/dygn",
          "noiseLevelDbA": "54–67 dB(A)",
          "filtrationClass": "HEPA H14 + ULPA U15 tillval (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_min = V_saneringszon (m³) × 10 h⁻¹ vid minst −20 Pa kontinuerligt undertryck",
          "applicationScopeSv": "Tillståndspliktig asbest-, PCB- och kvicksilversanering enligt AFS 2023:13."
        },
        {
          "unitId": "SP-AIRSCRUB-H14-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Sekundär Luftrenare med HEPA H14 + Impregnerad Aktivt Kol-Bädd (PCB / Hg-Ångfälla)",
          "airflowM3h": "500–2 000 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gas- och nanopartikelrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "48–59 dB(A)",
          "filtrationClass": "HEPA H14 + Svavelimpregnerat aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Kontakttid i kolbädd ≥ 0,2–0,4 s för adsorption av gasformiga PCB-kongener och Hg-ånga",
          "applicationScopeSv": "Sekundär luftrening vid PCB-fogsanering (SFS 2007:19) och kvicksilversanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)"
    },
    {
      "serviceSlug": "brandsanering",
      "serviceName": "Brandsanering",
      "primaryEquipmentCategory": "TORRISBLASTRARE_KRYO",
      "primaryEquipmentModelSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C) + HEPA H14/ULPA U15 Undertrycksfläkt & Aktivt Kol-Scrubber",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "1 500–8 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) under torrisblästring och sotrivning",
      "dehumidificationCapacityLitersPerDay": "40–160 L/dygn vid efterföljande släckvattentorkning",
      "powerSupply": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "28–96 kWh/dygn",
      "noiseLevelDbA": "49–62 dB(A) (luftrening) / 75–85 dB(A) under aktiv CO₂-blästring",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + Aktivt kol",
      "sizingFormulaSv": "Q_rök (m³/h) = V_brandzon (m³) × 12 ACH; Kolbäddsvikt (kg) ≥ Q (m³/h) × 0,015 kg/(m³/h) för PAH/VOC-mättnad",
      "taxClassification": "NONE_B2B_INSURANCE",
      "regulatoryBasisSv": "AFS 2023:10 (Kemiska arbetsmiljörisker · PAH/isocyanater/HCl/HF), SS-EN ISO 8502-6 (Bresle), SS-EN 1504-3 & SS-EN ISO 14644-1.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CRYO-CO2-PRO",
          "equipmentCategory": "TORRISBLASTRARE_KRYO",
          "modelNameSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C, 3 mm pellets, 2–14 bar) för Takstolar, Betong & Vindkraft/BESS",
          "airflowM3h": "3 500–6 500 m³/h (kombinerat med lokal HEPA H14-utsugskåpa)",
          "targetAchRange": "12–15 ACH i blästringszon",
          "dehumidificationCapacityLitersPerDay": "0 L/dygn (100 % vattenfri sublimering från fast CO₂ till gas)",
          "powerSupply": "400V 3-fas 16A/32A (CEE)",
          "voltagePhase": "400V",
          "amperageRating": "16A / 32A",
          "supportedPowerTokens": [
            "400V",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "35–90 kWh/arbetsdag",
          "noiseLevelDbA": "75–84 dB(A) under blästring",
          "filtrationClass": "Extern HEPA H14-utsugning (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Pelletsförbrukning = 25–60 kg CO₂/h vid avverkning 8–20 m² sotad konstruktionsyta/h",
          "applicationScopeSv": "Sekundäravfallsfri sotsanering av takstolar, murverk, parkeringsgarage och energiinfrastruktur."
        },
        {
          "unitId": "SP-ESD-ULPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "ESD-Jordad ULPA U15 / HEPA H14 Renrumsvakuumsug & Undertrycksfläkt för Datacenter & Ställverk",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–15 ACH (ISO 14644-1 Klass 8)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,9995 % partikelavskiljning vid MPPS)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–34 kWh/dygn",
          "noiseLevelDbA": "51–62 dB(A)",
          "filtrationClass": "ULPA U15 (≥ 99,9995 %) + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_renrum = V_serverhall (m³) × 12 ACH för att nå ISO 14644-1 Klass 8 (< 3 520 000 partiklar ≥ 0,5 µm/m³)",
          "applicationScopeSv": "Spänningssatt partikel- och sotsanering i datacenter, serverhallar, UPS-rum och elcentraler."
        },
        {
          "unitId": "SP-SCRUB-PAH-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Brandgas- & PAH-Luftrenare med HEPA H14 + Kemisorberande Aktivt Kol (HCl/HF/VOC)",
          "airflowM3h": "750–2 800 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (kemisk gas- och partikeladsorption)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–22 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + Kaliumkarbonat-/aktivt kolbädd (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lokal × 8 ACH; kontinuerlig drift tills TVOC < 0,20 mg/m³",
          "applicationScopeSv": "Adsorption av brandlukt, PAH, akrolein, fenoler och sura rökgaser."
        }
      ],
      "equipmentCategoryCode": "TORRISBLASTRARE_KRYO",
      "powerSupplyRequirement": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF"
    },
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    },
    {
      "serviceSlug": "socialsanering",
      "serviceName": "Socialsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Luftrenare, Konvektionsvärmesystem (56–60 °C Vägglöss) & Enzymatisk ULV-Dimning",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "500–3 000 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) med luktlås mot trapphus",
      "dehumidificationCapacityLitersPerDay": "20–45 L/dygn vid fuktskadat golv efter urin-/vätskeskada",
      "powerSupply": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "8–85 kWh/dygn",
      "noiseLevelDbA": "45–59 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_luktlås (m³/h) = V_lägenhet (m³) × 8 ACH; P_värmebehandling (kW) = A_rum (m²) × 0,35 kW/m² för 56–60 °C kärntemperatur",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Miljöbalken 9 kap. 9 § (Olaitet för människors hälsa), Bostadsrättslagen 7 kap. 12 §, Jordabalken 12 kap., AFS 2018:4 & SS-EN 13697.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-SOC-AIR-H14-NH3",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Diskret Högeffekts Luftrenare med HEPA H14 + Kemisorberande Kolfilter mot Ammoniak & Urinsyra",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (luktlås och bioaerosolrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–20 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH med svagt undertryck mot entrédörr/trapphus",
          "applicationScopeSv": "Luktsäkrad misär- och samlarsanering i flerbostadshus utan luktutsläpp till grannar."
        },
        {
          "unitId": "SP-THERM-BEDBUG-58C",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Konvektionsvärmekanon (56–60 °C) med Trådlösa PT100-Kärngivare för Vägglöss & Ohyra",
          "airflowM3h": "1 200–3 600 m³/h recirkulation",
          "targetAchRange": "15–25 oms/h intern konvektion",
          "dehumidificationCapacityLitersPerDay": "Termisk uttorkning till RF < 25 % under värmefas",
          "powerSupply": "230V 1-fas 10A/16A (flera grupper) eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "32–85 kWh/behandlingscykel",
          "noiseLevelDbA": "54–63 dB(A)",
          "filtrationClass": "HEPA H13 / H14 förfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_termisk = 300–400 W/m² golvyta; 56–60 °C hålltid ≥ 180 min i madrass-/listkärna",
          "applicationScopeSv": "100 % kemikaliefri värmebekämpning av vägglöss (Cimex lectularius), pälsängrar och mattbaggar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol"
    },
    {
      "serviceSlug": "dodsbosanering",
      "serviceName": "Dödsbosanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Biosäkerhets-Undertrycksfläkt HEPA H14 + Aktivt Kol & Sporicid VHP-Torrdimmare (AFS 2018:4)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–2 800 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–12 luftomsättningar/timme (ACH) vid lik- och biofarasanering",
      "dehumidificationCapacityLitersPerDay": "20–40 L/dygn vid fuktskadat bjälklag",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "8–28 kWh/dygn",
      "noiseLevelDbA": "46–58 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte",
      "hepaStandard": "SS-EN 1822 (HEPA H14) + Aktivt kol",
      "sizingFormulaSv": "Q_bio (m³/h) = V_rum (m³) × 10 ACH; VHP-dimning = 8–12 ml/m³ enligt SS-EN 17272 (≥ 4-log₁₀ virucid/sporicid reduktion)",
      "taxClassification": "NONE_DODSBO",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker), Ärvdabalken (1958:637) 18 kap., Avfallsförordningen (2020:614) EWC 18 01 03* & SS-EN 14476.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-BIO-NP1800-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Portabel Bio-Undertrycksfläkt HEPA H14 + Aktivt Kol för Diskret Lägenhetsinneslutning",
          "airflowM3h": "600–2 500 m³/h",
          "targetAchRange": "10–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (bioaerosol- och luktspärr)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "7–22 kWh/dygn",
          "noiseLevelDbA": "46–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 10 ACH så att trapphus hålls 100 % luktfria",
          "applicationScopeSv": "Inneslutning vid eftersatt dödsbo och biologisk liksanering i flerbostadshus."
        },
        {
          "unitId": "SP-VHP-BIO-FOG",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sporicid VHP-Torrdimmare (SS-EN 17272 / SS-EN 14476) & EnzymatiskLågtrycksapplikator",
          "airflowM3h": "200–650 m³/h",
          "targetAchRange": "Helrums torrdimning",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–10 kWh/cykel",
          "noiseLevelDbA": "52–60 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "10 ml H₂O₂/PAA per m³ under ≥ 60 min för ATP < 25–50 RLU",
          "applicationScopeSv": "Slutdekontaminering efter friläggning av kontaminerat bjälklag vid dödsbosanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte"
    },
    {
      "serviceSlug": "nikotinsanering",
      "serviceName": "Nikotinsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Scrubber för Tredjehandsrök (THS / Nitrosaminer) & Termisk Ång-/VHP-Enhet",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "500–2 200 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH)",
      "dehumidificationCapacityLitersPerDay": "18–35 L/dygn vid snabbuttorkning efter alkalisk nikotintvätt",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–24 kWh/dygn",
      "noiseLevelDbA": "45–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_nikotin (m³/h) = V_bostad (m³) × 8 ACH under alkalisk dekontaminering och spärrmålning",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Miljöbalken 9 kap. 9 §, SS-EN ISO 16000-6 (TVOC) & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-THS-SCRUB-H14",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Tredjehandsrök-Scrubber med HEPA H14 + Aktivt Kolbädd (Adsorption av Nikotin & Pyridin)",
          "airflowM3h": "500–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 8 ACH tills ytnikotin ≤ 1,0 µg/100 cm²",
          "applicationScopeSv": "Eliminering av luftburen nikotin- och tjärlukt vid sanering av rökskadade lägenheter."
        },
        {
          "unitId": "SP-NIC-VHP-OX",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Peroxid-/Ozonreaktor för Ventilations- & Spaltneutralisering före Diffusionsspärr",
          "airflowM3h": "250–800 m³/h",
          "targetAchRange": "Sluten behandlingscykel i tömd bostad",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–12 kWh/cykel",
          "noiseLevelDbA": "50–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Oxidation efter genomförd 3-stegs tensid-/alkalitvätt så att noll tjärfilm återstår",
          "applicationScopeSv": "Neutralisering av nikotinrester i svåråtkomliga radiatorfickor och rörgenomföringar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)"
    },
    {
      "serviceSlug": "ozonbehandling",
      "serviceName": "Ozonbehandling",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Industriell Korona-Ozonreaktor (10 000–40 000 mg O₃/h) med MnO₂-Katalysator + HEPA H14 / Aktivt Kol-Efterrening",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "350–2 400 m³/h (cirkulations- och katalytisk avluftningskapacitet)",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) under katalytisk ozonnedbrytning före återinträde",
      "dehumidificationCapacityLitersPerDay": "Kräver föravfuktning till RF < 55 % före koronaurladdning (förhindrar HNO₃-bildning)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "4–28 kWh/behandlingscykel",
      "noiseLevelDbA": "48–59 dB(A) (endast i obemannat, hermetiskt förseglat och varningsskyltat utrymme)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol & AFS 2023:10",
      "sizingFormulaSv": "O₃-produktion (mg/h) = V_rum (m³) × måldos (15–40 mg/m³) × läckagefaktor (1,25); Frisläppning vid O₃ < 0,1 ppm (NGV enl. AFS 2023:10)",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:10 (Hygieniska gränsvärden O₃ NGV 0,1 ppm / KGV 0,3 ppm), Kemikalieinspektionens KIFS 2017:7 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-OZON-CORONA-40G",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sekvensstyrd Korona-Ozonreaktor (10–40 g O₃/h) med Elektro-Kemisk O₃-Sensor & Inbyggd MnO₂-Destruktor",
          "airflowM3h": "350–1 800 m³/h",
          "targetAchRange": "8–12 ACH under destruktionsfas",
          "dehumidificationCapacityLitersPerDay": "Förutsätter RF < 55 % i behandlingszonen",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "4–28 kWh/cykel",
          "noiseLevelDbA": "49–59 dB(A)",
          "filtrationClass": "HEPA H14 + MnO₂ / Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "CT-värde (ppm·min) dimensionerat efter VOC-/MVOC-belastning; återinträde först vid O₃ < 0,05–0,10 ppm",
          "applicationScopeSv": "Kontrollerad gasfasoxidation efter mekanisk källsanering i bostäder, krypgrunder, fordon och brandskadade utrymmen."
        },
        {
          "unitId": "SP-OZON-SCRUB-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Efterrenings-Scrubber med HEPA H14 + Impregnerat Aktivt Kol mot Sekundära Aldehyder & Ozonsönderfallsprodukter",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (adsorption av karbonyler och restozon)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–16 kWh/dygn",
          "noiseLevelDbA": "46–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_rum (m³) × 10 ACH under minst 4 h efter avslutad ozoncykel",
          "applicationScopeSv": "Eliminering av sekundära aldehyder/ketoner och restozon före överlämning."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator"
    },
    {
      "serviceSlug": "desinficering",
      "serviceName": "Desinficering",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Validerad VHP-/PAA-Torrdimgenerator (SS-EN 17272 / SS-EN 14476 / SS-EN 14675) + Lågtrycks Biofilms-Skumenhet",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "KONDENSAVFUKTARE"
      ],
      "airflowM3h": "300–3 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) vid renrums- och smittskyddsventilation",
      "dehumidificationCapacityLitersPerDay": "25–75 L/dygn efter våtsanering av källare, mejeri eller slakteri",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "6–42 kWh/dygn",
      "noiseLevelDbA": "47–62 dB(A)",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + SS-EN 17272",
      "sizingFormulaSv": "VHP-dos = 8–15 ml H₂O₂ (7,5–12 %) per m³ för ≥ 4-log₁₀ virucid (SS-EN 14476/14675) och ≥ 5-log₁₀ baktericid (SS-EN 1276/13697) reduktion",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN 14476, SS-EN 14675, SS-EN 1276, SS-EN 13697, SS-EN 17272, EG 852/2004 (HACCP), ISO 11290-1 (Listeria), WHO Ship Sanitation & LIVSFS 2022:12.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-VHP-17272-MED",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Automatiserad VHP-/Perättiksyra-Torrdimgenerator (SS-EN 17272) för Vård, Fartyg & Livsmedelsindustri",
          "airflowM3h": "300–1 200 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnad + katalytisk avluftning (10–15 ACH)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (torrdimma 5–10 µm utan fri kondens)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/cykel",
          "noiseLevelDbA": "51–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering 8–15 ml/m³; 6-log₁₀ sporicid reduktion verifierad med Geobacillus stearothermophilus-indikatorer",
          "applicationScopeSv": "Utbrottssanering av Norovirus på fartyg (WHO/IHR), Listeria i mejeri/slakteri (HACCP) och CPV-2 på veterinärklinik."
        },
        {
          "unitId": "SP-BIO-HEPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Medicinsk Undertryckshållare HEPA H14 / ULPA U15 för Isoleringszon, Sjukhus & Laboratorium",
          "airflowM3h": "800–3 500 m³/h",
          "targetAchRange": "12–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "10–38 kWh/dygn",
          "noiseLevelDbA": "47–59 dB(A)",
          "filtrationClass": "ULPA U15 + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_isoleringsrum (m³) × 12 ACH vid ΔP ≥ −15 till −30 Pa",
          "applicationScopeSv": "Patogensäker luftinneslutning vid avlopps-, sjukhus-, laboratorie- och dricksvattenreservoarsanering."
        },
        {
          "unitId": "SP-KOND-HYG-40",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Hygienklassad Rostfri Kondensavfuktare för Snabbuttorkning efter Källaröversvämning & Våtdesinfektion",
          "airflowM3h": "500–1 100 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "30–75 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–26 kWh/dygn",
          "noiseLevelDbA": "48–54 dB(A)",
          "filtrationClass": "HEPA H13 tvättbart kassettsystem (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "Uttorkning till ytfukt < 75 % RF inom 24–48 h efter våtdesinfektion för att hindra återväxt",
          "applicationScopeSv": "Snabb eftertorkning i våtutrymmen, källare och livsmedelslokaler."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare"
    },
    {
      "serviceSlug": "duvsanering",
      "serviceName": "Duvsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "HEPA H14-Undertrycksfläkt + H-Klassad Guano-Vakuumsug (AFS 2018:4 Skyddsnivå 3-rutin) & ULV-Desinfektor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "900–4 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–14 luftomsättningar/timme (ACH) på råvind, kyrktorn och i ljusgård",
      "dehumidificationCapacityLitersPerDay": "20–50 L/dygn efter våtsanering av balkong/vind",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "12–52 kWh/arbetsdag",
      "noiseLevelDbA": "51–65 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) & AFS 2018:4",
      "sizingFormulaSv": "Q_guano (m³/h) = V_vindssektion (m³) × 10 ACH efter sporicid befuktning av torr fågelträck före mekanisk vakuumsugning",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker, ornitos/psittakos), Avfallsförordningen (2020:614) EWC 18 01 03*, SS-EN 1822 & Kulturmiljölagen 4 kap. (kyrktorn).",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-GUANO-VAC-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Höglyftande H-Klassad Vakuumsug & HEPA H14-Undertrycksfläkt för Råvindar, Kyrktorn & Balkonger",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–14 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % bioaerosolavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "14–52 kWh/arbetsdag",
          "noiseLevelDbA": "53–65 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Undertryck ΔP ≥ 20 Pa mot trapphus/lägenheter under hela sugnings- och säckningsfasen",
          "applicationScopeSv": "Dammfri borttagning av fågelguano, bon och kontaminerad lösull på vindar och i kyrktorn."
        },
        {
          "unitId": "SP-GUANO-ULV-PAA",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV-Befuktnings- & Sporiciddimningsaggregat (Perättiksyra / Kaliumperoxomonosulfat) mot Ornitos & Fågelkvalster",
          "airflowM3h": "200–700 m³/h",
          "targetAchRange": "Ytbefuktning + rumsdimning (SS-EN 13697 / SS-EN 14476)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "52–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Befuktningsdos 0,3–0,5 L/m² guano 30 min före vakuumsugning för 0 % dammbildning",
          "applicationScopeSv": "Inaktivering av Chlamydia psittaci, Salmonella och fågelkvalster (Dermanyssus gallinae) före rivning."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer"
    }
  ],
  "serviceProfiles": [
    {
      "serviceSlug": "fuktsanering",
      "serviceName": "Fuktsanering",
      "primaryEquipmentCategory": "SORPTIONSAVFUKTARE",
      "primaryEquipmentModelSv": "Corroventa CTR / DST Sorptionsavfuktare + Tryck-/Sugturbin med HEPA H14-kassett",
      "secondaryEquipmentCategories": [
        "KONDENSAVFUKTARE",
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR"
      ],
      "airflowM3h": "200–1 400 m³/h (torrluftsflöde) / upp till 3 500 m³/h (cirkulationsfläkt)",
      "targetAchMin": 6,
      "targetAchRange": "6–12 luftomsättningar/timme (ACH) i torkzon",
      "dehumidificationCapacityLitersPerDay": "19–140 L/dygn vid 20 °C / 60 % RF (effektiv ned till −15 °C)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "18–68 kWh/dygn (MID-kalibrerad kWh-loggning per torkzon)",
      "noiseLevelDbA": "46–62 dB(A) vid 3 m (46–49 dB(A) i natt-/tystläge för kvarboende)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14)",
      "sizingFormulaSv": "Q_torrluft (m³/h) = V_rum (m³) × ACH (6–10 h⁻¹); Kapacitet_avfuktning (kg/dygn) = [m_vatten (kg) / t_mål (dygn)] + L_infiltration (kg/dygn)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, RBK-auktoriserad fuktmätningsmetodik, SS-EN 1822, Elsäkerhetsverkets ELSÄK-FS & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-SORP-A4-ES",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Sorptionsavfuktare A4/CTR ES + HEPA H14 Sug-/Tryckturbin (Skikt- & KL-Trätorkning)",
          "airflowM3h": "280–650 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "26–55 L/dygn vid 20 °C / 60 % RF",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "22–48 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + H13 kassett (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_konstruktion × 6 ACH; 1 turbinutgång per 4–6 m² flytande golv/KL-trä",
          "applicationScopeSv": "Isoleringstorkning i flytande golv, trossbotten, KL-trä (CLT), krypgrund och kalla utrymmen."
        },
        {
          "unitId": "SP-KOND-K50-ECO",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Kondensavfuktare K50/K90 Pro med Värmeåtervinning (Rumslufttorkning > 18 °C)",
          "airflowM3h": "450–950 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "35–90 L/dygn vid 30 °C / 80 % RF (22–52 L/dygn vid 20 °C / 60 % RF)",
          "powerSupply": "230V 1-fas 10A/16A (Schuko)",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "11–24 kWh/dygn",
          "noiseLevelDbA": "46–53 dB(A)",
          "filtrationClass": "HEPA H13 dammfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_kondens = A_golv (m²) × 0,6 L/(m²·dygn) vid rumstemperatur ≥ 20 °C",
          "applicationScopeSv": "Energieffektiv rumstorkning av betongplatta och puts i uppvärmda bostäder och lokaler."
        },
        {
          "unitId": "SP-IR-PANEL-3KW",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Infraröd (IR) Värmepanel & Termostatstyrd Konvektionsvärmare för Betong-/Stomtorkning",
          "airflowM3h": "0–1 800 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "Termisk ångtrycksökning (+200 % diffusionshastighet vid +10 °C ΔT)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "16–72 kWh/dygn",
          "noiseLevelDbA": "0–51 dB(A)",
          "filtrationClass": "Förfilter + extern HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_värme (W) = A_vägg (m²) × 250 W/m² (max yttemperatur 32–40 °C för massivträ/betong)",
          "applicationScopeSv": "Riktad djupuppvärmning av fuktiga betongväggar, valv och syllknutpunkter."
        }
      ],
      "equipmentCategoryCode": "SORPTIONSAVFUKTARE",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin"
    },
    {
      "serviceSlug": "mogelsanering",
      "serviceName": "Mögelsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Undertrycksfläkt HEPA H14 (SS-EN 1822) + Sorptionsavfuktare för Vind & Krypgrund",
      "secondaryEquipmentCategories": [
        "SORPTIONSAVFUKTARE",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–4 200 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) med ≥ 20 Pa undertryck",
      "dehumidificationCapacityLitersPerDay": "24–95 L/dygn vid kombinerad sorptionsavfuktning",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "14–56 kWh/dygn",
      "noiseLevelDbA": "47–64 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_undertryck (m³/h) = [L × B × H (m³) × 10 ACH] × 1,25 säkerhetsfaktor (mål ΔP ≥ −20 Pa)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Arbetsmiljöverkets AFS 2023:10, Folkhälsomyndighetens FoHMFS 2014:14 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-HEPA-NP2000",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Undertryckshållare NP-2000/NP-4000 med DOP-testat HEPA H14-filter & Trycklogg",
          "airflowM3h": "800–4 200 m³/h (steglöst varvtalsstyrd)",
          "targetAchRange": "10–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (partikel- och sporavskiljning 99,995 %)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "9–28 kWh/dygn",
          "noiseLevelDbA": "52–64 dB(A)",
          "filtrationClass": "HEPA H14 + H13 (SS-EN 1822) + Aktivt kol",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_zon (m³) × 10 ACH / 0,80 (inkl. tryckfall i frånluftsslang)",
          "applicationScopeSv": "Sporsäker inneslutning vid rivning av mögel- och hussvampsangripet byggmaterial samt undertaksplenum."
        },
        {
          "unitId": "SP-SORP-KRYP-30",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Permanent/Mobil Sorptionsavfuktare för Krypgrund & Kallvind med Hygrostatstyrning",
          "airflowM3h": "210–550 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "19–45 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–32 kWh/dygn",
          "noiseLevelDbA": "47–55 dB(A)",
          "filtrationClass": "HEPA H13 / H14 processfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_krypgrund (m³) × 1,5–3,0 oms/h för att hålla RF < 65–70 %",
          "applicationScopeSv": "Fuktsäkring av krypgrunder, torpargrunder, kallvindar och kyrkovindar."
        },
        {
          "unitId": "SP-VHP-ULV-MOGEL",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV Torrdimgenerator (VHP / Stabiliserad Väteperoxid 5–12 %, Partikelstorlek 5–15 µm)",
          "airflowM3h": "150–600 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnadsdimning (SS-EN 17272)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (sporicid aerosolbehandling)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "58–66 dB(A) (i obemannat utrymme)",
          "filtrationClass": "Katalytisk H14 + Aktivt kol-nedbrytning efter inverkningstid",
          "supportedFiltrationClasses": [
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering = 6–12 ml H₂O₂-lösning per m³ rumsvolym under 60–120 min kontakttid",
          "applicationScopeSv": "Rumslig sporicid dekontaminering av dolda spalter, bjälklagsfickor och råvindar."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)"
    },
    {
      "serviceSlug": "asbestsanering",
      "serviceName": "Asbestsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "DOP-Testad HEPA H14 Undertryckscentral + 3-Stegs Våtsluss & H-Klassad Asbestvakuumsug (AFS 2023:13)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "1 000–6 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "≥ 10 luftomsättningar/timme (ACH) i asbestzon (AFS 2023:13)",
      "dehumidificationCapacityLitersPerDay": "Våtdämpning med penetrerande tensidvätska (noll dammning)",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "16–64 kWh/dygn (kontinuerlig 24/7-drift under hela inneslutningstiden)",
      "noiseLevelDbA": "54–67 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)",
      "hepaStandard": "SS-EN 1822 (HEPA H14 / ULPA U15) & AFS 2023:13",
      "sizingFormulaSv": "Q_asbest (m³/h) = V_inneslutning (m³) × 10 ACH; Undertryck ΔP ≥ 20–30 Pa med akustiskt/optiskt tryckfallslarm",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:13 (Asbest), SS-EN 1822 (HEPA H14), SS-EN 60335-2-69 Klass H & Avfallsförordningen (2020:614) EWC 17 06 05*.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-ASBEST-NP4500-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Asbest-Undertrycksaggregat NP-4500 med HEPA H14, Differenstrycksskrivare & Nödströmslarm",
          "airflowM3h": "1 200–6 000 m³/h",
          "targetAchRange": "10–20 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % asbestfiberavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "18–64 kWh/dygn",
          "noiseLevelDbA": "54–67 dB(A)",
          "filtrationClass": "HEPA H14 + ULPA U15 tillval (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_min = V_saneringszon (m³) × 10 h⁻¹ vid minst −20 Pa kontinuerligt undertryck",
          "applicationScopeSv": "Tillståndspliktig asbest-, PCB- och kvicksilversanering enligt AFS 2023:13."
        },
        {
          "unitId": "SP-AIRSCRUB-H14-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Sekundär Luftrenare med HEPA H14 + Impregnerad Aktivt Kol-Bädd (PCB / Hg-Ångfälla)",
          "airflowM3h": "500–2 000 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gas- och nanopartikelrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "48–59 dB(A)",
          "filtrationClass": "HEPA H14 + Svavelimpregnerat aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Kontakttid i kolbädd ≥ 0,2–0,4 s för adsorption av gasformiga PCB-kongener och Hg-ånga",
          "applicationScopeSv": "Sekundär luftrening vid PCB-fogsanering (SFS 2007:19) och kvicksilversanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)"
    },
    {
      "serviceSlug": "brandsanering",
      "serviceName": "Brandsanering",
      "primaryEquipmentCategory": "TORRISBLASTRARE_KRYO",
      "primaryEquipmentModelSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C) + HEPA H14/ULPA U15 Undertrycksfläkt & Aktivt Kol-Scrubber",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "1 500–8 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) under torrisblästring och sotrivning",
      "dehumidificationCapacityLitersPerDay": "40–160 L/dygn vid efterföljande släckvattentorkning",
      "powerSupply": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "28–96 kWh/dygn",
      "noiseLevelDbA": "49–62 dB(A) (luftrening) / 75–85 dB(A) under aktiv CO₂-blästring",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + Aktivt kol",
      "sizingFormulaSv": "Q_rök (m³/h) = V_brandzon (m³) × 12 ACH; Kolbäddsvikt (kg) ≥ Q (m³/h) × 0,015 kg/(m³/h) för PAH/VOC-mättnad",
      "taxClassification": "NONE_B2B_INSURANCE",
      "regulatoryBasisSv": "AFS 2023:10 (Kemiska arbetsmiljörisker · PAH/isocyanater/HCl/HF), SS-EN ISO 8502-6 (Bresle), SS-EN 1504-3 & SS-EN ISO 14644-1.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CRYO-CO2-PRO",
          "equipmentCategory": "TORRISBLASTRARE_KRYO",
          "modelNameSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C, 3 mm pellets, 2–14 bar) för Takstolar, Betong & Vindkraft/BESS",
          "airflowM3h": "3 500–6 500 m³/h (kombinerat med lokal HEPA H14-utsugskåpa)",
          "targetAchRange": "12–15 ACH i blästringszon",
          "dehumidificationCapacityLitersPerDay": "0 L/dygn (100 % vattenfri sublimering från fast CO₂ till gas)",
          "powerSupply": "400V 3-fas 16A/32A (CEE)",
          "voltagePhase": "400V",
          "amperageRating": "16A / 32A",
          "supportedPowerTokens": [
            "400V",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "35–90 kWh/arbetsdag",
          "noiseLevelDbA": "75–84 dB(A) under blästring",
          "filtrationClass": "Extern HEPA H14-utsugning (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Pelletsförbrukning = 25–60 kg CO₂/h vid avverkning 8–20 m² sotad konstruktionsyta/h",
          "applicationScopeSv": "Sekundäravfallsfri sotsanering av takstolar, murverk, parkeringsgarage och energiinfrastruktur."
        },
        {
          "unitId": "SP-ESD-ULPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "ESD-Jordad ULPA U15 / HEPA H14 Renrumsvakuumsug & Undertrycksfläkt för Datacenter & Ställverk",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–15 ACH (ISO 14644-1 Klass 8)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,9995 % partikelavskiljning vid MPPS)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–34 kWh/dygn",
          "noiseLevelDbA": "51–62 dB(A)",
          "filtrationClass": "ULPA U15 (≥ 99,9995 %) + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_renrum = V_serverhall (m³) × 12 ACH för att nå ISO 14644-1 Klass 8 (< 3 520 000 partiklar ≥ 0,5 µm/m³)",
          "applicationScopeSv": "Spänningssatt partikel- och sotsanering i datacenter, serverhallar, UPS-rum och elcentraler."
        },
        {
          "unitId": "SP-SCRUB-PAH-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Brandgas- & PAH-Luftrenare med HEPA H14 + Kemisorberande Aktivt Kol (HCl/HF/VOC)",
          "airflowM3h": "750–2 800 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (kemisk gas- och partikeladsorption)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–22 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + Kaliumkarbonat-/aktivt kolbädd (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lokal × 8 ACH; kontinuerlig drift tills TVOC < 0,20 mg/m³",
          "applicationScopeSv": "Adsorption av brandlukt, PAH, akrolein, fenoler och sura rökgaser."
        }
      ],
      "equipmentCategoryCode": "TORRISBLASTRARE_KRYO",
      "powerSupplyRequirement": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF"
    },
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    },
    {
      "serviceSlug": "socialsanering",
      "serviceName": "Socialsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Luftrenare, Konvektionsvärmesystem (56–60 °C Vägglöss) & Enzymatisk ULV-Dimning",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "500–3 000 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) med luktlås mot trapphus",
      "dehumidificationCapacityLitersPerDay": "20–45 L/dygn vid fuktskadat golv efter urin-/vätskeskada",
      "powerSupply": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "8–85 kWh/dygn",
      "noiseLevelDbA": "45–59 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_luktlås (m³/h) = V_lägenhet (m³) × 8 ACH; P_värmebehandling (kW) = A_rum (m²) × 0,35 kW/m² för 56–60 °C kärntemperatur",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Miljöbalken 9 kap. 9 § (Olaitet för människors hälsa), Bostadsrättslagen 7 kap. 12 §, Jordabalken 12 kap., AFS 2018:4 & SS-EN 13697.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-SOC-AIR-H14-NH3",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Diskret Högeffekts Luftrenare med HEPA H14 + Kemisorberande Kolfilter mot Ammoniak & Urinsyra",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (luktlås och bioaerosolrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–20 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH med svagt undertryck mot entrédörr/trapphus",
          "applicationScopeSv": "Luktsäkrad misär- och samlarsanering i flerbostadshus utan luktutsläpp till grannar."
        },
        {
          "unitId": "SP-THERM-BEDBUG-58C",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Konvektionsvärmekanon (56–60 °C) med Trådlösa PT100-Kärngivare för Vägglöss & Ohyra",
          "airflowM3h": "1 200–3 600 m³/h recirkulation",
          "targetAchRange": "15–25 oms/h intern konvektion",
          "dehumidificationCapacityLitersPerDay": "Termisk uttorkning till RF < 25 % under värmefas",
          "powerSupply": "230V 1-fas 10A/16A (flera grupper) eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "32–85 kWh/behandlingscykel",
          "noiseLevelDbA": "54–63 dB(A)",
          "filtrationClass": "HEPA H13 / H14 förfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_termisk = 300–400 W/m² golvyta; 56–60 °C hålltid ≥ 180 min i madrass-/listkärna",
          "applicationScopeSv": "100 % kemikaliefri värmebekämpning av vägglöss (Cimex lectularius), pälsängrar och mattbaggar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol"
    },
    {
      "serviceSlug": "dodsbosanering",
      "serviceName": "Dödsbosanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Biosäkerhets-Undertrycksfläkt HEPA H14 + Aktivt Kol & Sporicid VHP-Torrdimmare (AFS 2018:4)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–2 800 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–12 luftomsättningar/timme (ACH) vid lik- och biofarasanering",
      "dehumidificationCapacityLitersPerDay": "20–40 L/dygn vid fuktskadat bjälklag",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "8–28 kWh/dygn",
      "noiseLevelDbA": "46–58 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte",
      "hepaStandard": "SS-EN 1822 (HEPA H14) + Aktivt kol",
      "sizingFormulaSv": "Q_bio (m³/h) = V_rum (m³) × 10 ACH; VHP-dimning = 8–12 ml/m³ enligt SS-EN 17272 (≥ 4-log₁₀ virucid/sporicid reduktion)",
      "taxClassification": "NONE_DODSBO",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker), Ärvdabalken (1958:637) 18 kap., Avfallsförordningen (2020:614) EWC 18 01 03* & SS-EN 14476.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-BIO-NP1800-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Portabel Bio-Undertrycksfläkt HEPA H14 + Aktivt Kol för Diskret Lägenhetsinneslutning",
          "airflowM3h": "600–2 500 m³/h",
          "targetAchRange": "10–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (bioaerosol- och luktspärr)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "7–22 kWh/dygn",
          "noiseLevelDbA": "46–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 10 ACH så att trapphus hålls 100 % luktfria",
          "applicationScopeSv": "Inneslutning vid eftersatt dödsbo och biologisk liksanering i flerbostadshus."
        },
        {
          "unitId": "SP-VHP-BIO-FOG",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sporicid VHP-Torrdimmare (SS-EN 17272 / SS-EN 14476) & EnzymatiskLågtrycksapplikator",
          "airflowM3h": "200–650 m³/h",
          "targetAchRange": "Helrums torrdimning",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–10 kWh/cykel",
          "noiseLevelDbA": "52–60 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "10 ml H₂O₂/PAA per m³ under ≥ 60 min för ATP < 25–50 RLU",
          "applicationScopeSv": "Slutdekontaminering efter friläggning av kontaminerat bjälklag vid dödsbosanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte"
    },
    {
      "serviceSlug": "nikotinsanering",
      "serviceName": "Nikotinsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Scrubber för Tredjehandsrök (THS / Nitrosaminer) & Termisk Ång-/VHP-Enhet",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "500–2 200 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH)",
      "dehumidificationCapacityLitersPerDay": "18–35 L/dygn vid snabbuttorkning efter alkalisk nikotintvätt",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–24 kWh/dygn",
      "noiseLevelDbA": "45–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_nikotin (m³/h) = V_bostad (m³) × 8 ACH under alkalisk dekontaminering och spärrmålning",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Miljöbalken 9 kap. 9 §, SS-EN ISO 16000-6 (TVOC) & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-THS-SCRUB-H14",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Tredjehandsrök-Scrubber med HEPA H14 + Aktivt Kolbädd (Adsorption av Nikotin & Pyridin)",
          "airflowM3h": "500–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 8 ACH tills ytnikotin ≤ 1,0 µg/100 cm²",
          "applicationScopeSv": "Eliminering av luftburen nikotin- och tjärlukt vid sanering av rökskadade lägenheter."
        },
        {
          "unitId": "SP-NIC-VHP-OX",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Peroxid-/Ozonreaktor för Ventilations- & Spaltneutralisering före Diffusionsspärr",
          "airflowM3h": "250–800 m³/h",
          "targetAchRange": "Sluten behandlingscykel i tömd bostad",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–12 kWh/cykel",
          "noiseLevelDbA": "50–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Oxidation efter genomförd 3-stegs tensid-/alkalitvätt så att noll tjärfilm återstår",
          "applicationScopeSv": "Neutralisering av nikotinrester i svåråtkomliga radiatorfickor och rörgenomföringar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)"
    },
    {
      "serviceSlug": "ozonbehandling",
      "serviceName": "Ozonbehandling",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Industriell Korona-Ozonreaktor (10 000–40 000 mg O₃/h) med MnO₂-Katalysator + HEPA H14 / Aktivt Kol-Efterrening",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "350–2 400 m³/h (cirkulations- och katalytisk avluftningskapacitet)",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) under katalytisk ozonnedbrytning före återinträde",
      "dehumidificationCapacityLitersPerDay": "Kräver föravfuktning till RF < 55 % före koronaurladdning (förhindrar HNO₃-bildning)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "4–28 kWh/behandlingscykel",
      "noiseLevelDbA": "48–59 dB(A) (endast i obemannat, hermetiskt förseglat och varningsskyltat utrymme)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol & AFS 2023:10",
      "sizingFormulaSv": "O₃-produktion (mg/h) = V_rum (m³) × måldos (15–40 mg/m³) × läckagefaktor (1,25); Frisläppning vid O₃ < 0,1 ppm (NGV enl. AFS 2023:10)",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:10 (Hygieniska gränsvärden O₃ NGV 0,1 ppm / KGV 0,3 ppm), Kemikalieinspektionens KIFS 2017:7 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-OZON-CORONA-40G",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sekvensstyrd Korona-Ozonreaktor (10–40 g O₃/h) med Elektro-Kemisk O₃-Sensor & Inbyggd MnO₂-Destruktor",
          "airflowM3h": "350–1 800 m³/h",
          "targetAchRange": "8–12 ACH under destruktionsfas",
          "dehumidificationCapacityLitersPerDay": "Förutsätter RF < 55 % i behandlingszonen",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "4–28 kWh/cykel",
          "noiseLevelDbA": "49–59 dB(A)",
          "filtrationClass": "HEPA H14 + MnO₂ / Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "CT-värde (ppm·min) dimensionerat efter VOC-/MVOC-belastning; återinträde först vid O₃ < 0,05–0,10 ppm",
          "applicationScopeSv": "Kontrollerad gasfasoxidation efter mekanisk källsanering i bostäder, krypgrunder, fordon och brandskadade utrymmen."
        },
        {
          "unitId": "SP-OZON-SCRUB-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Efterrenings-Scrubber med HEPA H14 + Impregnerat Aktivt Kol mot Sekundära Aldehyder & Ozonsönderfallsprodukter",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (adsorption av karbonyler och restozon)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–16 kWh/dygn",
          "noiseLevelDbA": "46–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_rum (m³) × 10 ACH under minst 4 h efter avslutad ozoncykel",
          "applicationScopeSv": "Eliminering av sekundära aldehyder/ketoner och restozon före överlämning."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator"
    },
    {
      "serviceSlug": "desinficering",
      "serviceName": "Desinficering",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Validerad VHP-/PAA-Torrdimgenerator (SS-EN 17272 / SS-EN 14476 / SS-EN 14675) + Lågtrycks Biofilms-Skumenhet",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "KONDENSAVFUKTARE"
      ],
      "airflowM3h": "300–3 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) vid renrums- och smittskyddsventilation",
      "dehumidificationCapacityLitersPerDay": "25–75 L/dygn efter våtsanering av källare, mejeri eller slakteri",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "6–42 kWh/dygn",
      "noiseLevelDbA": "47–62 dB(A)",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + SS-EN 17272",
      "sizingFormulaSv": "VHP-dos = 8–15 ml H₂O₂ (7,5–12 %) per m³ för ≥ 4-log₁₀ virucid (SS-EN 14476/14675) och ≥ 5-log₁₀ baktericid (SS-EN 1276/13697) reduktion",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN 14476, SS-EN 14675, SS-EN 1276, SS-EN 13697, SS-EN 17272, EG 852/2004 (HACCP), ISO 11290-1 (Listeria), WHO Ship Sanitation & LIVSFS 2022:12.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-VHP-17272-MED",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Automatiserad VHP-/Perättiksyra-Torrdimgenerator (SS-EN 17272) för Vård, Fartyg & Livsmedelsindustri",
          "airflowM3h": "300–1 200 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnad + katalytisk avluftning (10–15 ACH)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (torrdimma 5–10 µm utan fri kondens)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/cykel",
          "noiseLevelDbA": "51–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering 8–15 ml/m³; 6-log₁₀ sporicid reduktion verifierad med Geobacillus stearothermophilus-indikatorer",
          "applicationScopeSv": "Utbrottssanering av Norovirus på fartyg (WHO/IHR), Listeria i mejeri/slakteri (HACCP) och CPV-2 på veterinärklinik."
        },
        {
          "unitId": "SP-BIO-HEPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Medicinsk Undertryckshållare HEPA H14 / ULPA U15 för Isoleringszon, Sjukhus & Laboratorium",
          "airflowM3h": "800–3 500 m³/h",
          "targetAchRange": "12–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "10–38 kWh/dygn",
          "noiseLevelDbA": "47–59 dB(A)",
          "filtrationClass": "ULPA U15 + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_isoleringsrum (m³) × 12 ACH vid ΔP ≥ −15 till −30 Pa",
          "applicationScopeSv": "Patogensäker luftinneslutning vid avlopps-, sjukhus-, laboratorie- och dricksvattenreservoarsanering."
        },
        {
          "unitId": "SP-KOND-HYG-40",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Hygienklassad Rostfri Kondensavfuktare för Snabbuttorkning efter Källaröversvämning & Våtdesinfektion",
          "airflowM3h": "500–1 100 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "30–75 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–26 kWh/dygn",
          "noiseLevelDbA": "48–54 dB(A)",
          "filtrationClass": "HEPA H13 tvättbart kassettsystem (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "Uttorkning till ytfukt < 75 % RF inom 24–48 h efter våtdesinfektion för att hindra återväxt",
          "applicationScopeSv": "Snabb eftertorkning i våtutrymmen, källare och livsmedelslokaler."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare"
    },
    {
      "serviceSlug": "duvsanering",
      "serviceName": "Duvsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "HEPA H14-Undertrycksfläkt + H-Klassad Guano-Vakuumsug (AFS 2018:4 Skyddsnivå 3-rutin) & ULV-Desinfektor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "900–4 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–14 luftomsättningar/timme (ACH) på råvind, kyrktorn och i ljusgård",
      "dehumidificationCapacityLitersPerDay": "20–50 L/dygn efter våtsanering av balkong/vind",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "12–52 kWh/arbetsdag",
      "noiseLevelDbA": "51–65 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) & AFS 2018:4",
      "sizingFormulaSv": "Q_guano (m³/h) = V_vindssektion (m³) × 10 ACH efter sporicid befuktning av torr fågelträck före mekanisk vakuumsugning",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker, ornitos/psittakos), Avfallsförordningen (2020:614) EWC 18 01 03*, SS-EN 1822 & Kulturmiljölagen 4 kap. (kyrktorn).",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-GUANO-VAC-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Höglyftande H-Klassad Vakuumsug & HEPA H14-Undertrycksfläkt för Råvindar, Kyrktorn & Balkonger",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–14 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % bioaerosolavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "14–52 kWh/arbetsdag",
          "noiseLevelDbA": "53–65 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Undertryck ΔP ≥ 20 Pa mot trapphus/lägenheter under hela sugnings- och säckningsfasen",
          "applicationScopeSv": "Dammfri borttagning av fågelguano, bon och kontaminerad lösull på vindar och i kyrktorn."
        },
        {
          "unitId": "SP-GUANO-ULV-PAA",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV-Befuktnings- & Sporiciddimningsaggregat (Perättiksyra / Kaliumperoxomonosulfat) mot Ornitos & Fågelkvalster",
          "airflowM3h": "200–700 m³/h",
          "targetAchRange": "Ytbefuktning + rumsdimning (SS-EN 13697 / SS-EN 14476)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "52–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Befuktningsdos 0,3–0,5 L/m² guano 30 min före vakuumsugning för 0 % dammbildning",
          "applicationScopeSv": "Inaktivering av Chlamydia psittaci, Salmonella och fågelkvalster (Dermanyssus gallinae) före rivning."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer"
    }
  ],
  "equipmentFleet": [
    {
      "serviceSlug": "fuktsanering",
      "serviceName": "Fuktsanering",
      "primaryEquipmentCategory": "SORPTIONSAVFUKTARE",
      "primaryEquipmentModelSv": "Corroventa CTR / DST Sorptionsavfuktare + Tryck-/Sugturbin med HEPA H14-kassett",
      "secondaryEquipmentCategories": [
        "KONDENSAVFUKTARE",
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR"
      ],
      "airflowM3h": "200–1 400 m³/h (torrluftsflöde) / upp till 3 500 m³/h (cirkulationsfläkt)",
      "targetAchMin": 6,
      "targetAchRange": "6–12 luftomsättningar/timme (ACH) i torkzon",
      "dehumidificationCapacityLitersPerDay": "19–140 L/dygn vid 20 °C / 60 % RF (effektiv ned till −15 °C)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "18–68 kWh/dygn (MID-kalibrerad kWh-loggning per torkzon)",
      "noiseLevelDbA": "46–62 dB(A) vid 3 m (46–49 dB(A) i natt-/tystläge för kvarboende)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14)",
      "sizingFormulaSv": "Q_torrluft (m³/h) = V_rum (m³) × ACH (6–10 h⁻¹); Kapacitet_avfuktning (kg/dygn) = [m_vatten (kg) / t_mål (dygn)] + L_infiltration (kg/dygn)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, RBK-auktoriserad fuktmätningsmetodik, SS-EN 1822, Elsäkerhetsverkets ELSÄK-FS & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-SORP-A4-ES",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Sorptionsavfuktare A4/CTR ES + HEPA H14 Sug-/Tryckturbin (Skikt- & KL-Trätorkning)",
          "airflowM3h": "280–650 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "26–55 L/dygn vid 20 °C / 60 % RF",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "22–48 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + H13 kassett (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_konstruktion × 6 ACH; 1 turbinutgång per 4–6 m² flytande golv/KL-trä",
          "applicationScopeSv": "Isoleringstorkning i flytande golv, trossbotten, KL-trä (CLT), krypgrund och kalla utrymmen."
        },
        {
          "unitId": "SP-KOND-K50-ECO",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Kondensavfuktare K50/K90 Pro med Värmeåtervinning (Rumslufttorkning > 18 °C)",
          "airflowM3h": "450–950 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "35–90 L/dygn vid 30 °C / 80 % RF (22–52 L/dygn vid 20 °C / 60 % RF)",
          "powerSupply": "230V 1-fas 10A/16A (Schuko)",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "11–24 kWh/dygn",
          "noiseLevelDbA": "46–53 dB(A)",
          "filtrationClass": "HEPA H13 dammfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_kondens = A_golv (m²) × 0,6 L/(m²·dygn) vid rumstemperatur ≥ 20 °C",
          "applicationScopeSv": "Energieffektiv rumstorkning av betongplatta och puts i uppvärmda bostäder och lokaler."
        },
        {
          "unitId": "SP-IR-PANEL-3KW",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Infraröd (IR) Värmepanel & Termostatstyrd Konvektionsvärmare för Betong-/Stomtorkning",
          "airflowM3h": "0–1 800 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "Termisk ångtrycksökning (+200 % diffusionshastighet vid +10 °C ΔT)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "16–72 kWh/dygn",
          "noiseLevelDbA": "0–51 dB(A)",
          "filtrationClass": "Förfilter + extern HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_värme (W) = A_vägg (m²) × 250 W/m² (max yttemperatur 32–40 °C för massivträ/betong)",
          "applicationScopeSv": "Riktad djupuppvärmning av fuktiga betongväggar, valv och syllknutpunkter."
        }
      ],
      "equipmentCategoryCode": "SORPTIONSAVFUKTARE",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A (CEE) för storskalig stomtorkning",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % vid MPPS enl. SS-EN 1822) + G4 förfilter i sugturbin"
    },
    {
      "serviceSlug": "mogelsanering",
      "serviceName": "Mögelsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Undertrycksfläkt HEPA H14 (SS-EN 1822) + Sorptionsavfuktare för Vind & Krypgrund",
      "secondaryEquipmentCategories": [
        "SORPTIONSAVFUKTARE",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–4 200 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) med ≥ 20 Pa undertryck",
      "dehumidificationCapacityLitersPerDay": "24–95 L/dygn vid kombinerad sorptionsavfuktning",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "14–56 kWh/dygn",
      "noiseLevelDbA": "47–64 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_undertryck (m³/h) = [L × B × H (m³) × 10 ACH] × 1,25 säkerhetsfaktor (mål ΔP ≥ −20 Pa)",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Arbetsmiljöverkets AFS 2023:10, Folkhälsomyndighetens FoHMFS 2014:14 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-HEPA-NP2000",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Undertryckshållare NP-2000/NP-4000 med DOP-testat HEPA H14-filter & Trycklogg",
          "airflowM3h": "800–4 200 m³/h (steglöst varvtalsstyrd)",
          "targetAchRange": "10–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (partikel- och sporavskiljning 99,995 %)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "9–28 kWh/dygn",
          "noiseLevelDbA": "52–64 dB(A)",
          "filtrationClass": "HEPA H14 + H13 (SS-EN 1822) + Aktivt kol",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_zon (m³) × 10 ACH / 0,80 (inkl. tryckfall i frånluftsslang)",
          "applicationScopeSv": "Sporsäker inneslutning vid rivning av mögel- och hussvampsangripet byggmaterial samt undertaksplenum."
        },
        {
          "unitId": "SP-SORP-KRYP-30",
          "equipmentCategory": "SORPTIONSAVFUKTARE",
          "modelNameSv": "Permanent/Mobil Sorptionsavfuktare för Krypgrund & Kallvind med Hygrostatstyrning",
          "airflowM3h": "210–550 m³/h",
          "targetAchRange": "4–8 ACH",
          "dehumidificationCapacityLitersPerDay": "19–45 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–32 kWh/dygn",
          "noiseLevelDbA": "47–55 dB(A)",
          "filtrationClass": "HEPA H13 / H14 processfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_torrluft = V_krypgrund (m³) × 1,5–3,0 oms/h för att hålla RF < 65–70 %",
          "applicationScopeSv": "Fuktsäkring av krypgrunder, torpargrunder, kallvindar och kyrkovindar."
        },
        {
          "unitId": "SP-VHP-ULV-MOGEL",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV Torrdimgenerator (VHP / Stabiliserad Väteperoxid 5–12 %, Partikelstorlek 5–15 µm)",
          "airflowM3h": "150–600 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnadsdimning (SS-EN 17272)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (sporicid aerosolbehandling)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "58–66 dB(A) (i obemannat utrymme)",
          "filtrationClass": "Katalytisk H14 + Aktivt kol-nedbrytning efter inverkningstid",
          "supportedFiltrationClasses": [
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering = 6–12 ml H₂O₂-lösning per m³ rumsvolym under 60–120 min kontakttid",
          "applicationScopeSv": "Rumslig sporicid dekontaminering av dolda spalter, bjälklagsfickor och råvindar."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Aktivt kol (MVOC-adsorption)"
    },
    {
      "serviceSlug": "asbestsanering",
      "serviceName": "Asbestsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "DOP-Testad HEPA H14 Undertryckscentral + 3-Stegs Våtsluss & H-Klassad Asbestvakuumsug (AFS 2023:13)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "1 000–6 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "≥ 10 luftomsättningar/timme (ACH) i asbestzon (AFS 2023:13)",
      "dehumidificationCapacityLitersPerDay": "Våtdämpning med penetrerande tensidvätska (noll dammning)",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "16–64 kWh/dygn (kontinuerlig 24/7-drift under hela inneslutningstiden)",
      "noiseLevelDbA": "54–67 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)",
      "hepaStandard": "SS-EN 1822 (HEPA H14 / ULPA U15) & AFS 2023:13",
      "sizingFormulaSv": "Q_asbest (m³/h) = V_inneslutning (m³) × 10 ACH; Undertryck ΔP ≥ 20–30 Pa med akustiskt/optiskt tryckfallslarm",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:13 (Asbest), SS-EN 1822 (HEPA H14), SS-EN 60335-2-69 Klass H & Avfallsförordningen (2020:614) EWC 17 06 05*.",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-ASBEST-NP4500-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Asbest-Undertrycksaggregat NP-4500 med HEPA H14, Differenstrycksskrivare & Nödströmslarm",
          "airflowM3h": "1 200–6 000 m³/h",
          "targetAchRange": "10–20 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % asbestfiberavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "18–64 kWh/dygn",
          "noiseLevelDbA": "54–67 dB(A)",
          "filtrationClass": "HEPA H14 + ULPA U15 tillval (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_min = V_saneringszon (m³) × 10 h⁻¹ vid minst −20 Pa kontinuerligt undertryck",
          "applicationScopeSv": "Tillståndspliktig asbest-, PCB- och kvicksilversanering enligt AFS 2023:13."
        },
        {
          "unitId": "SP-AIRSCRUB-H14-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Sekundär Luftrenare med HEPA H14 + Impregnerad Aktivt Kol-Bädd (PCB / Hg-Ångfälla)",
          "airflowM3h": "500–2 000 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gas- och nanopartikelrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "48–59 dB(A)",
          "filtrationClass": "HEPA H14 + Svavelimpregnerat aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Kontakttid i kolbädd ≥ 0,2–0,4 s för adsorption av gasformiga PCB-kongener och Hg-ånga",
          "applicationScopeSv": "Sekundär luftrening vid PCB-fogsanering (SFS 2007:19) och kvicksilversanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för storzon och vakuumsugbil",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) + Dammsugarklass H (SS-EN 60335-2-69)"
    },
    {
      "serviceSlug": "brandsanering",
      "serviceName": "Brandsanering",
      "primaryEquipmentCategory": "TORRISBLASTRARE_KRYO",
      "primaryEquipmentModelSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C) + HEPA H14/ULPA U15 Undertrycksfläkt & Aktivt Kol-Scrubber",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "1 500–8 000 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) under torrisblästring och sotrivning",
      "dehumidificationCapacityLitersPerDay": "40–160 L/dygn vid efterföljande släckvattentorkning",
      "powerSupply": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "28–96 kWh/dygn",
      "noiseLevelDbA": "49–62 dB(A) (luftrening) / 75–85 dB(A) under aktiv CO₂-blästring",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + Aktivt kol",
      "sizingFormulaSv": "Q_rök (m³/h) = V_brandzon (m³) × 12 ACH; Kolbäddsvikt (kg) ≥ Q (m³/h) × 0,015 kg/(m³/h) för PAH/VOC-mättnad",
      "taxClassification": "NONE_B2B_INSURANCE",
      "regulatoryBasisSv": "AFS 2023:10 (Kemiska arbetsmiljörisker · PAH/isocyanater/HCl/HF), SS-EN ISO 8502-6 (Bresle), SS-EN 1504-3 & SS-EN ISO 14644-1.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CRYO-CO2-PRO",
          "equipmentCategory": "TORRISBLASTRARE_KRYO",
          "modelNameSv": "Kryogen CO₂-Torrisblästrare (−78,5 °C, 3 mm pellets, 2–14 bar) för Takstolar, Betong & Vindkraft/BESS",
          "airflowM3h": "3 500–6 500 m³/h (kombinerat med lokal HEPA H14-utsugskåpa)",
          "targetAchRange": "12–15 ACH i blästringszon",
          "dehumidificationCapacityLitersPerDay": "0 L/dygn (100 % vattenfri sublimering från fast CO₂ till gas)",
          "powerSupply": "400V 3-fas 16A/32A (CEE)",
          "voltagePhase": "400V",
          "amperageRating": "16A / 32A",
          "supportedPowerTokens": [
            "400V",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "35–90 kWh/arbetsdag",
          "noiseLevelDbA": "75–84 dB(A) under blästring",
          "filtrationClass": "Extern HEPA H14-utsugning (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "Pelletsförbrukning = 25–60 kg CO₂/h vid avverkning 8–20 m² sotad konstruktionsyta/h",
          "applicationScopeSv": "Sekundäravfallsfri sotsanering av takstolar, murverk, parkeringsgarage och energiinfrastruktur."
        },
        {
          "unitId": "SP-ESD-ULPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "ESD-Jordad ULPA U15 / HEPA H14 Renrumsvakuumsug & Undertrycksfläkt för Datacenter & Ställverk",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–15 ACH (ISO 14644-1 Klass 8)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,9995 % partikelavskiljning vid MPPS)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–34 kWh/dygn",
          "noiseLevelDbA": "51–62 dB(A)",
          "filtrationClass": "ULPA U15 (≥ 99,9995 %) + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q_renrum = V_serverhall (m³) × 12 ACH för att nå ISO 14644-1 Klass 8 (< 3 520 000 partiklar ≥ 0,5 µm/m³)",
          "applicationScopeSv": "Spänningssatt partikel- och sotsanering i datacenter, serverhallar, UPS-rum och elcentraler."
        },
        {
          "unitId": "SP-SCRUB-PAH-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Brandgas- & PAH-Luftrenare med HEPA H14 + Kemisorberande Aktivt Kol (HCl/HF/VOC)",
          "airflowM3h": "750–2 800 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (kemisk gas- och partikeladsorption)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "8–22 kWh/dygn",
          "noiseLevelDbA": "48–58 dB(A)",
          "filtrationClass": "HEPA H14 + Kaliumkarbonat-/aktivt kolbädd (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lokal × 8 ACH; kontinuerlig drift tills TVOC < 0,20 mg/m³",
          "applicationScopeSv": "Adsorption av brandlukt, PAH, akrolein, fenoler och sura rökgaser."
        }
      ],
      "equipmentCategoryCode": "TORRISBLASTRARE_KRYO",
      "powerSupplyRequirement": "400V 3-fas 16A/32A (CEE) för torrisblästring/kompressor samt 230V 1-fas 10A/16A för luftrening",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Chemisorb Aktivt Kol mot PAH, HCl och HF"
    },
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    },
    {
      "serviceSlug": "socialsanering",
      "serviceName": "Socialsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Luftrenare, Konvektionsvärmesystem (56–60 °C Vägglöss) & Enzymatisk ULV-Dimning",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "TERMISK_VARMEKANON_IR",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "500–3 000 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) med luktlås mot trapphus",
      "dehumidificationCapacityLitersPerDay": "20–45 L/dygn vid fuktskadat golv efter urin-/vätskeskada",
      "powerSupply": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "8–85 kWh/dygn",
      "noiseLevelDbA": "45–59 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_luktlås (m³/h) = V_lägenhet (m³) × 8 ACH; P_värmebehandling (kW) = A_rum (m²) × 0,35 kW/m² för 56–60 °C kärntemperatur",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Miljöbalken 9 kap. 9 § (Olaitet för människors hälsa), Bostadsrättslagen 7 kap. 12 §, Jordabalken 12 kap., AFS 2018:4 & SS-EN 13697.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-SOC-AIR-H14-NH3",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Diskret Högeffekts Luftrenare med HEPA H14 + Kemisorberande Kolfilter mot Ammoniak & Urinsyra",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (luktlås och bioaerosolrening)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–20 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH med svagt undertryck mot entrédörr/trapphus",
          "applicationScopeSv": "Luktsäkrad misär- och samlarsanering i flerbostadshus utan luktutsläpp till grannar."
        },
        {
          "unitId": "SP-THERM-BEDBUG-58C",
          "equipmentCategory": "TERMISK_VARMEKANON_IR",
          "modelNameSv": "Konvektionsvärmekanon (56–60 °C) med Trådlösa PT100-Kärngivare för Vägglöss & Ohyra",
          "airflowM3h": "1 200–3 600 m³/h recirkulation",
          "targetAchRange": "15–25 oms/h intern konvektion",
          "dehumidificationCapacityLitersPerDay": "Termisk uttorkning till RF < 25 % under värmefas",
          "powerSupply": "230V 1-fas 10A/16A (flera grupper) eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "32–85 kWh/behandlingscykel",
          "noiseLevelDbA": "54–63 dB(A)",
          "filtrationClass": "HEPA H13 / H14 förfilter (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "EN_1822"
          ],
          "sizingFormulaSv": "P_termisk = 300–400 W/m² golvyta; 56–60 °C hålltid ≥ 180 min i madrass-/listkärna",
          "applicationScopeSv": "100 % kemikaliefri värmebekämpning av vägglöss (Cimex lectularius), pälsängrar och mattbaggar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (bostadsuttag) samt 400V 3-fas 16A/32A vid helrums värmebehandling (56–60 °C)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Ammoniak-/Svavelväteimpregnerat Aktivt Kol"
    },
    {
      "serviceSlug": "dodsbosanering",
      "serviceName": "Dödsbosanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "Biosäkerhets-Undertrycksfläkt HEPA H14 + Aktivt Kol & Sporicid VHP-Torrdimmare (AFS 2018:4)",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "VHP_FOGGER_OZON"
      ],
      "airflowM3h": "600–2 800 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–12 luftomsättningar/timme (ACH) vid lik- och biofarasanering",
      "dehumidificationCapacityLitersPerDay": "20–40 L/dygn vid fuktskadat bjälklag",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "8–28 kWh/dygn",
      "noiseLevelDbA": "46–58 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte",
      "hepaStandard": "SS-EN 1822 (HEPA H14) + Aktivt kol",
      "sizingFormulaSv": "Q_bio (m³/h) = V_rum (m³) × 10 ACH; VHP-dimning = 8–12 ml/m³ enligt SS-EN 17272 (≥ 4-log₁₀ virucid/sporicid reduktion)",
      "taxClassification": "NONE_DODSBO",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker), Ärvdabalken (1958:637) 18 kap., Avfallsförordningen (2020:614) EWC 18 01 03* & SS-EN 14476.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-BIO-NP1800-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Portabel Bio-Undertrycksfläkt HEPA H14 + Aktivt Kol för Diskret Lägenhetsinneslutning",
          "airflowM3h": "600–2 500 m³/h",
          "targetAchRange": "10–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (bioaerosol- och luktspärr)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "7–22 kWh/dygn",
          "noiseLevelDbA": "46–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 10 ACH så att trapphus hålls 100 % luktfria",
          "applicationScopeSv": "Inneslutning vid eftersatt dödsbo och biologisk liksanering i flerbostadshus."
        },
        {
          "unitId": "SP-VHP-BIO-FOG",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sporicid VHP-Torrdimmare (SS-EN 17272 / SS-EN 14476) & EnzymatiskLågtrycksapplikator",
          "airflowM3h": "200–650 m³/h",
          "targetAchRange": "Helrums torrdimning",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–10 kWh/cykel",
          "noiseLevelDbA": "52–60 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "10 ml H₂O₂/PAA per m³ under ≥ 60 min för ATP < 25–50 RLU",
          "applicationScopeSv": "Slutdekontaminering efter friläggning av kontaminerat bjälklag vid dödsbosanering."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Putrescin, Kadaverin och Svavelväte"
    },
    {
      "serviceSlug": "nikotinsanering",
      "serviceName": "Nikotinsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "HEPA H14 + Aktivt Kol-Scrubber för Tredjehandsrök (THS / Nitrosaminer) & Termisk Ång-/VHP-Enhet",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "500–2 200 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH)",
      "dehumidificationCapacityLitersPerDay": "18–35 L/dygn vid snabbuttorkning efter alkalisk nikotintvätt",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–24 kWh/dygn",
      "noiseLevelDbA": "45–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_nikotin (m³/h) = V_bostad (m³) × 8 ACH under alkalisk dekontaminering och spärrmålning",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Boverkets BBR 6:5, Miljöbalken 9 kap. 9 §, SS-EN ISO 16000-6 (TVOC) & AFS 2023:10.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-THS-SCRUB-H14",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Tredjehandsrök-Scrubber med HEPA H14 + Aktivt Kolbädd (Adsorption av Nikotin & Pyridin)",
          "airflowM3h": "500–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "6–18 kWh/dygn",
          "noiseLevelDbA": "45–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_lägenhet (m³) × 8 ACH tills ytnikotin ≤ 1,0 µg/100 cm²",
          "applicationScopeSv": "Eliminering av luftburen nikotin- och tjärlukt vid sanering av rökskadade lägenheter."
        },
        {
          "unitId": "SP-NIC-VHP-OX",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Peroxid-/Ozonreaktor för Ventilations- & Spaltneutralisering före Diffusionsspärr",
          "airflowM3h": "250–800 m³/h",
          "targetAchRange": "Sluten behandlingscykel i tömd bostad",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–12 kWh/cykel",
          "noiseLevelDbA": "50–58 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Oxidation efter genomförd 3-stegs tensid-/alkalitvätt så att noll tjärfilm återstår",
          "applicationScopeSv": "Neutralisering av nikotinrester i svåråtkomliga radiatorfickor och rörgenomföringar."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Aktivt Kol mot Pyridin, Nikotin och TSNAs (NNK/NNN)"
    },
    {
      "serviceSlug": "ozonbehandling",
      "serviceName": "Ozonbehandling",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Industriell Korona-Ozonreaktor (10 000–40 000 mg O₃/h) med MnO₂-Katalysator + HEPA H14 / Aktivt Kol-Efterrening",
      "secondaryEquipmentCategories": [
        "LUFTRENARE_HEPA_KOL",
        "UNDERTRYCKSFLAKT_HEPA"
      ],
      "airflowM3h": "350–2 400 m³/h (cirkulations- och katalytisk avluftningskapacitet)",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) under katalytisk ozonnedbrytning före återinträde",
      "dehumidificationCapacityLitersPerDay": "Kräver föravfuktning till RF < 55 % före koronaurladdning (förhindrar HNO₃-bildning)",
      "powerSupply": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "4–28 kWh/behandlingscykel",
      "noiseLevelDbA": "48–59 dB(A) (endast i obemannat, hermetiskt förseglat och varningsskyltat utrymme)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol & AFS 2023:10",
      "sizingFormulaSv": "O₃-produktion (mg/h) = V_rum (m³) × måldos (15–40 mg/m³) × läckagefaktor (1,25); Frisläppning vid O₃ < 0,1 ppm (NGV enl. AFS 2023:10)",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2023:10 (Hygieniska gränsvärden O₃ NGV 0,1 ppm / KGV 0,3 ppm), Kemikalieinspektionens KIFS 2017:7 & SS-EN 1822.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-OZON-CORONA-40G",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Sekvensstyrd Korona-Ozonreaktor (10–40 g O₃/h) med Elektro-Kemisk O₃-Sensor & Inbyggd MnO₂-Destruktor",
          "airflowM3h": "350–1 800 m³/h",
          "targetAchRange": "8–12 ACH under destruktionsfas",
          "dehumidificationCapacityLitersPerDay": "Förutsätter RF < 55 % i behandlingszonen",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "4–28 kWh/cykel",
          "noiseLevelDbA": "49–59 dB(A)",
          "filtrationClass": "HEPA H14 + MnO₂ / Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "CT-värde (ppm·min) dimensionerat efter VOC-/MVOC-belastning; återinträde först vid O₃ < 0,05–0,10 ppm",
          "applicationScopeSv": "Kontrollerad gasfasoxidation efter mekanisk källsanering i bostäder, krypgrunder, fordon och brandskadade utrymmen."
        },
        {
          "unitId": "SP-OZON-SCRUB-KOL",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Efterrenings-Scrubber med HEPA H14 + Impregnerat Aktivt Kol mot Sekundära Aldehyder & Ozonsönderfallsprodukter",
          "airflowM3h": "500–2 400 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (adsorption av karbonyler och restozon)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–16 kWh/dygn",
          "noiseLevelDbA": "46–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_rum (m³) × 10 ACH under minst 4 h efter avslutad ozoncykel",
          "applicationScopeSv": "Eliminering av sekundära aldehyder/ketoner och restozon före överlämning."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko) samt 400V 3-fas 16A/32A vid industriell storvolymsozonering",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + Mangandioxid (MnO₂) & Aktivt Kol-Katalysator"
    },
    {
      "serviceSlug": "desinficering",
      "serviceName": "Desinficering",
      "primaryEquipmentCategory": "VHP_FOGGER_OZON",
      "primaryEquipmentModelSv": "Validerad VHP-/PAA-Torrdimgenerator (SS-EN 17272 / SS-EN 14476 / SS-EN 14675) + Lågtrycks Biofilms-Skumenhet",
      "secondaryEquipmentCategories": [
        "UNDERTRYCKSFLAKT_HEPA",
        "LUFTRENARE_HEPA_KOL",
        "KONDENSAVFUKTARE"
      ],
      "airflowM3h": "300–3 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–15 luftomsättningar/timme (ACH) vid renrums- och smittskyddsventilation",
      "dehumidificationCapacityLitersPerDay": "25–75 L/dygn efter våtsanering av källare, mejeri eller slakteri",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "6–42 kWh/dygn",
      "noiseLevelDbA": "47–62 dB(A)",
      "filtrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare",
      "hepaStandard": "SS-EN 1822 (H13 / H14 / U15) + SS-EN 17272",
      "sizingFormulaSv": "VHP-dos = 8–15 ml H₂O₂ (7,5–12 %) per m³ för ≥ 4-log₁₀ virucid (SS-EN 14476/14675) och ≥ 5-log₁₀ baktericid (SS-EN 1276/13697) reduktion",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN 14476, SS-EN 14675, SS-EN 1276, SS-EN 13697, SS-EN 17272, EG 852/2004 (HACCP), ISO 11290-1 (Listeria), WHO Ship Sanitation & LIVSFS 2022:12.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-VHP-17272-MED",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Automatiserad VHP-/Perättiksyra-Torrdimgenerator (SS-EN 17272) för Vård, Fartyg & Livsmedelsindustri",
          "airflowM3h": "300–1 200 m³/h dispersionsflöde",
          "targetAchRange": "Rumslig mättnad + katalytisk avluftning (10–15 ACH)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (torrdimma 5–10 µm utan fri kondens)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/cykel",
          "noiseLevelDbA": "51–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Dosering 8–15 ml/m³; 6-log₁₀ sporicid reduktion verifierad med Geobacillus stearothermophilus-indikatorer",
          "applicationScopeSv": "Utbrottssanering av Norovirus på fartyg (WHO/IHR), Listeria i mejeri/slakteri (HACCP) och CPV-2 på veterinärklinik."
        },
        {
          "unitId": "SP-BIO-HEPA-U15",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Medicinsk Undertryckshållare HEPA H14 / ULPA U15 för Isoleringszon, Sjukhus & Laboratorium",
          "airflowM3h": "800–3 500 m³/h",
          "targetAchRange": "12–15 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "10–38 kWh/dygn",
          "noiseLevelDbA": "47–59 dB(A)",
          "filtrationClass": "ULPA U15 + HEPA H14 (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "U15",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_isoleringsrum (m³) × 12 ACH vid ΔP ≥ −15 till −30 Pa",
          "applicationScopeSv": "Patogensäker luftinneslutning vid avlopps-, sjukhus-, laboratorie- och dricksvattenreservoarsanering."
        },
        {
          "unitId": "SP-KOND-HYG-40",
          "equipmentCategory": "KONDENSAVFUKTARE",
          "modelNameSv": "Hygienklassad Rostfri Kondensavfuktare för Snabbuttorkning efter Källaröversvämning & Våtdesinfektion",
          "airflowM3h": "500–1 100 m³/h",
          "targetAchRange": "6–10 ACH",
          "dehumidificationCapacityLitersPerDay": "30–75 L/dygn",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "12–26 kWh/dygn",
          "noiseLevelDbA": "48–54 dB(A)",
          "filtrationClass": "HEPA H13 tvättbart kassettsystem (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "EN_1822"
          ],
          "sizingFormulaSv": "Uttorkning till ytfukt < 75 % RF inom 24–48 h efter våtdesinfektion för att hindra återväxt",
          "applicationScopeSv": "Snabb eftertorkning i våtutrymmen, källare och livsmedelslokaler."
        }
      ],
      "equipmentCategoryCode": "VHP_FOGGER_OZON",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för industriell CIP/skumdesinfektion",
      "hepaFiltrationClass": "HEPA H14 / ULPA U15 (SS-EN 1822) + Katalytisk Peroxidnedbrytare"
    },
    {
      "serviceSlug": "duvsanering",
      "serviceName": "Duvsanering",
      "primaryEquipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
      "primaryEquipmentModelSv": "HEPA H14-Undertrycksfläkt + H-Klassad Guano-Vakuumsug (AFS 2018:4 Skyddsnivå 3-rutin) & ULV-Desinfektor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "LUFTRENARE_HEPA_KOL"
      ],
      "airflowM3h": "900–4 500 m³/h",
      "targetAchMin": 10,
      "targetAchRange": "10–14 luftomsättningar/timme (ACH) på råvind, kyrktorn och i ljusgård",
      "dehumidificationCapacityLitersPerDay": "20–50 L/dygn efter våtsanering av balkong/vind",
      "powerSupply": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "voltagePhase": "230V / 400V",
      "amperageRating": "10A / 16A / 32A",
      "dailyEnergyConsumptionKwh": "12–52 kWh/arbetsdag",
      "noiseLevelDbA": "51–65 dB(A)",
      "filtrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) & AFS 2018:4",
      "sizingFormulaSv": "Q_guano (m³/h) = V_vindssektion (m³) × 10 ACH efter sporicid befuktning av torr fågelträck före mekanisk vakuumsugning",
      "taxClassification": "ROT_30",
      "regulatoryBasisSv": "Arbetsmiljöverkets AFS 2018:4 (Smittrisker, ornitos/psittakos), Avfallsförordningen (2020:614) EWC 18 01 03*, SS-EN 1822 & Kulturmiljölagen 4 kap. (kyrktorn).",
      "lantmaterietCfArNumberRequired": true,
      "equipmentUnits": [
        {
          "unitId": "SP-GUANO-VAC-H14",
          "equipmentCategory": "UNDERTRYCKSFLAKT_HEPA",
          "modelNameSv": "Höglyftande H-Klassad Vakuumsug & HEPA H14-Undertrycksfläkt för Råvindar, Kyrktorn & Balkonger",
          "airflowM3h": "900–4 500 m³/h",
          "targetAchRange": "10–14 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (99,995 % bioaerosolavskiljning)",
          "powerSupply": "230V 1-fas 10A/16A eller 400V 3-fas 16A/32A",
          "voltagePhase": "230V / 400V",
          "amperageRating": "10A / 16A / 32A",
          "supportedPowerTokens": [
            "230V",
            "400V",
            "10A",
            "16A",
            "32A"
          ],
          "dailyEnergyConsumptionKwh": "14–52 kWh/arbetsdag",
          "noiseLevelDbA": "53–65 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Undertryck ΔP ≥ 20 Pa mot trapphus/lägenheter under hela sugnings- och säckningsfasen",
          "applicationScopeSv": "Dammfri borttagning av fågelguano, bon och kontaminerad lösull på vindar och i kyrktorn."
        },
        {
          "unitId": "SP-GUANO-ULV-PAA",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "ULV-Befuktnings- & Sporiciddimningsaggregat (Perättiksyra / Kaliumperoxomonosulfat) mot Ornitos & Fågelkvalster",
          "airflowM3h": "200–700 m³/h",
          "targetAchRange": "Ytbefuktning + rumsdimning (SS-EN 13697 / SS-EN 14476)",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "3–9 kWh/cykel",
          "noiseLevelDbA": "52–61 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Befuktningsdos 0,3–0,5 L/m² guano 30 min före vakuumsugning för 0 % dammbildning",
          "applicationScopeSv": "Inaktivering av Chlamydia psittaci, Salmonella och fågelkvalster (Dermanyssus gallinae) före rivning."
        }
      ],
      "equipmentCategoryCode": "UNDERTRYCKSFLAKT_HEPA",
      "powerSupplyRequirement": "230V 1-fas 10A/16A samt 400V 3-fas 16A/32A för höglyftande vakuumsug på kyrkovind/tak",
      "hepaFiltrationClass": "HEPA H14 (≥ 99,995 % MPPS enl. SS-EN 1822) mot Chlamydia psittaci & Cryptococcus-sporer"
    }
  ],
  "municipalities": [
    {
      "citySlug": "stockholm",
      "cityName": "Stockholm",
      "kommunName": "Stockholms stad",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "60–90 minuter",
      "depotAddress": "Västberga Allé 25",
      "depotPostalCode": "126 30",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Stockholms stad",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Stockholms stad från lokal depå (Västberga Allé 25)."
    },
    {
      "citySlug": "goteborg",
      "cityName": "Göteborg",
      "kommunName": "Göteborgs stad",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "60–90 minuter",
      "depotAddress": "August Barks gata 18",
      "depotPostalCode": "421 32",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Göteborgs stad",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Göteborgs stad från lokal depå (August Barks gata 18)."
    },
    {
      "citySlug": "malmo",
      "cityName": "Malmö",
      "kommunName": "Malmö stad",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "60–90 minuter",
      "depotAddress": "Jägersrovägen 202",
      "depotPostalCode": "213 75",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Malmö stad",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Malmö stad från lokal depå (Jägersrovägen 202)."
    },
    {
      "citySlug": "uppsala",
      "cityName": "Uppsala",
      "kommunName": "Uppsala kommun",
      "regionSlug": "uppsala-lan",
      "regionName": "Uppsala län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Stålgatan 14",
      "depotPostalCode": "754 50",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Uppsala kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Uppsala kommun från lokal depå (Stålgatan 14)."
    },
    {
      "citySlug": "vasteras",
      "cityName": "Västerås",
      "kommunName": "Västerås stad",
      "regionSlug": "vastmanlands-lan",
      "regionName": "Västmanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hallsta Gårdsgata 12",
      "depotPostalCode": "721 38",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Västerås stad",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Västerås stad från lokal depå (Hallsta Gårdsgata 12)."
    },
    {
      "citySlug": "orebro",
      "cityName": "Örebro",
      "kommunName": "Örebro kommun",
      "regionSlug": "orebro-lan",
      "regionName": "Örebro län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Aspholmsvägen 9",
      "depotPostalCode": "702 27",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Örebro kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Örebro kommun från lokal depå (Aspholmsvägen 9)."
    },
    {
      "citySlug": "linkoping",
      "cityName": "Linköping",
      "kommunName": "Linköpings kommun",
      "regionSlug": "ostergotlands-lan",
      "regionName": "Östergötlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Roxtorpsgatan 16",
      "depotPostalCode": "582 73",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Linköpings kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Linköpings kommun från lokal depå (Roxtorpsgatan 16)."
    },
    {
      "citySlug": "helsingborg",
      "cityName": "Helsingborg",
      "kommunName": "Helsingborgs stad",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Muskötgatan 11",
      "depotPostalCode": "254 66",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Helsingborgs stad",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Helsingborgs stad från lokal depå (Muskötgatan 11)."
    },
    {
      "citySlug": "jonkoping",
      "cityName": "Jönköping",
      "kommunName": "Jönköpings kommun",
      "regionSlug": "jonkopings-lan",
      "regionName": "Jönköpings län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hedenstorpsvägen 7",
      "depotPostalCode": "555 93",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Jönköpings kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Jönköpings kommun från lokal depå (Hedenstorpsvägen 7)."
    },
    {
      "citySlug": "norrkoping",
      "cityName": "Norrköping",
      "kommunName": "Norrköpings kommun",
      "regionSlug": "ostergotlands-lan",
      "regionName": "Östergötlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Koppargatan 19",
      "depotPostalCode": "602 23",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Norrköpings kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Norrköpings kommun från lokal depå (Koppargatan 19)."
    },
    {
      "citySlug": "lund",
      "cityName": "Lund",
      "kommunName": "Lunds kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kalkstensvägen 15",
      "depotPostalCode": "224 78",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Lunds kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Lunds kommun från lokal depå (Kalkstensvägen 15)."
    },
    {
      "citySlug": "umea",
      "cityName": "Umeå",
      "kommunName": "Umeå kommun",
      "regionSlug": "vasterbottens-lan",
      "regionName": "Västerbottens län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Spårvägen 10",
      "depotPostalCode": "901 31",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Umeå kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Umeå kommun från lokal depå (Spårvägen 10)."
    },
    {
      "citySlug": "gavle",
      "cityName": "Gävle",
      "kommunName": "Gävle kommun",
      "regionSlug": "gavleborgs-lan",
      "regionName": "Gävleborgs län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kryddstigen 22",
      "depotPostalCode": "802 92",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Gävle kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Gävle kommun från lokal depå (Kryddstigen 22)."
    },
    {
      "citySlug": "boras",
      "cityName": "Borås",
      "kommunName": "Borås stad",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Företagsgatan 24",
      "depotPostalCode": "504 64",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Borås stad",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Borås stad från lokal depå (Företagsgatan 24)."
    },
    {
      "citySlug": "sodertalje",
      "cityName": "Södertälje",
      "kommunName": "Södertälje kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Morabergsvägen 14",
      "depotPostalCode": "152 42",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Södertälje kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Södertälje kommun från lokal depå (Morabergsvägen 14)."
    },
    {
      "citySlug": "eskilstuna",
      "cityName": "Eskilstuna",
      "kommunName": "Eskilstuna kommun",
      "regionSlug": "sodermanlands-lan",
      "regionName": "Södermanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Mått Johanssons väg 18",
      "depotPostalCode": "633 46",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Eskilstuna kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Eskilstuna kommun från lokal depå (Mått Johanssons väg 18)."
    },
    {
      "citySlug": "halmstad",
      "cityName": "Halmstad",
      "kommunName": "Halmstads kommun",
      "regionSlug": "hallands-lan",
      "regionName": "Hallands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kundvägen 8",
      "depotPostalCode": "302 41",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Halmstads kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Halmstads kommun från lokal depå (Kundvägen 8)."
    },
    {
      "citySlug": "vaxjo",
      "cityName": "Växjö",
      "kommunName": "Växjö kommun",
      "regionSlug": "kronobergs-lan",
      "regionName": "Kronobergs län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hejaregatan 12",
      "depotPostalCode": "352 46",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Växjö kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Växjö kommun från lokal depå (Hejaregatan 12)."
    },
    {
      "citySlug": "karlstad",
      "cityName": "Karlstad",
      "kommunName": "Karlstads kommun",
      "regionSlug": "varmlands-lan",
      "regionName": "Värmlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Spärrgatan 6",
      "depotPostalCode": "653 41",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Karlstads kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Karlstads kommun från lokal depå (Spärrgatan 6)."
    },
    {
      "citySlug": "sundsvall",
      "cityName": "Sundsvall",
      "kommunName": "Sundsvalls kommun",
      "regionSlug": "vasternorrlands-lan",
      "regionName": "Västernorrlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Bultgatan 14",
      "depotPostalCode": "853 50",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Sundsvalls kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Sundsvalls kommun från lokal depå (Bultgatan 14)."
    },
    {
      "citySlug": "ostersund",
      "cityName": "Östersund",
      "kommunName": "Östersunds kommun",
      "regionSlug": "jamtlands-lan",
      "regionName": "Jämtlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Chaufförvägen 19",
      "depotPostalCode": "831 48",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Östersunds kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Östersunds kommun från lokal depå (Chaufförvägen 19)."
    },
    {
      "citySlug": "trollhattan",
      "cityName": "Trollhättan",
      "kommunName": "Trollhättans stad",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kardanvägen 21",
      "depotPostalCode": "461 38",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Trollhättans stad",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Trollhättans stad från lokal depå (Kardanvägen 21)."
    },
    {
      "citySlug": "lulea",
      "cityName": "Luleå",
      "kommunName": "Luleå kommun",
      "regionSlug": "norrbottens-lan",
      "regionName": "Norrbottens län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Bangårdsgatan 11",
      "depotPostalCode": "972 35",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Luleå kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Luleå kommun från lokal depå (Bangårdsgatan 11)."
    },
    {
      "citySlug": "lidingo",
      "cityName": "Lidingö",
      "kommunName": "Lidingö stad",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Södra Kungsvägen 64",
      "depotPostalCode": "181 32",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Lidingö stad",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Lidingö stad från lokal depå (Södra Kungsvägen 64)."
    },
    {
      "citySlug": "tumba",
      "cityName": "Tumba",
      "kommunName": "Botkyrka kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Skyttbrinksvägen 18",
      "depotPostalCode": "147 39",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Botkyrka kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Botkyrka kommun från lokal depå (Skyttbrinksvägen 18)."
    },
    {
      "citySlug": "kalmar",
      "cityName": "Kalmar",
      "kommunName": "Kalmar kommun",
      "regionSlug": "kalmar-lan",
      "regionName": "Kalmar län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Franska vägen 22",
      "depotPostalCode": "393 56",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Kalmar kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Kalmar kommun från lokal depå (Franska vägen 22)."
    },
    {
      "citySlug": "falun",
      "cityName": "Falun",
      "kommunName": "Falu kommun",
      "regionSlug": "dalarnas-lan",
      "regionName": "Dalarnas län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Ingarvsvägen 9",
      "depotPostalCode": "791 77",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Falu kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Falu kommun från lokal depå (Ingarvsvägen 9)."
    },
    {
      "citySlug": "borlange",
      "cityName": "Borlänge",
      "kommunName": "Borlänge kommun",
      "regionSlug": "dalarnas-lan",
      "regionName": "Dalarnas län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Bragegatan 14",
      "depotPostalCode": "784 33",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Borlänge kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Borlänge kommun från lokal depå (Bragegatan 14)."
    },
    {
      "citySlug": "skovde",
      "cityName": "Skövde",
      "kommunName": "Skövde kommun",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Batterivägen 12",
      "depotPostalCode": "541 34",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Skövde kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Skövde kommun från lokal depå (Batterivägen 12)."
    },
    {
      "citySlug": "karlskrona",
      "cityName": "Karlskrona",
      "kommunName": "Karlskrona kommun",
      "regionSlug": "blekinge-lan",
      "regionName": "Blekinge län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Gullbernavägen 16",
      "depotPostalCode": "371 47",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Karlskrona kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Karlskrona kommun från lokal depå (Gullbernavägen 16)."
    },
    {
      "citySlug": "kristianstad",
      "cityName": "Kristianstad",
      "kommunName": "Kristianstads kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Industrigatan 28",
      "depotPostalCode": "291 36",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Kristianstads kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Kristianstads kommun från lokal depå (Industrigatan 28)."
    },
    {
      "citySlug": "skelleftea",
      "cityName": "Skellefteå",
      "kommunName": "Skellefteå kommun",
      "regionSlug": "vasterbottens-lan",
      "regionName": "Västerbottens län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Tjärnvägen 14",
      "depotPostalCode": "931 61",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Skellefteå kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Skellefteå kommun från lokal depå (Tjärnvägen 14)."
    },
    {
      "citySlug": "uddevalla",
      "cityName": "Uddevalla",
      "kommunName": "Uddevalla kommun",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kurödsvägen 11",
      "depotPostalCode": "451 55",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Uddevalla kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Uddevalla kommun från lokal depå (Kurödsvägen 11)."
    },
    {
      "citySlug": "nykoping",
      "cityName": "Nyköping",
      "kommunName": "Nyköpings kommun",
      "regionSlug": "sodermanlands-lan",
      "regionName": "Södermanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Blommenhovsvägen 20",
      "depotPostalCode": "611 39",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Nyköpings kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Nyköpings kommun från lokal depå (Blommenhovsvägen 20)."
    },
    {
      "citySlug": "varberg",
      "cityName": "Varberg",
      "kommunName": "Varbergs kommun",
      "regionSlug": "hallands-lan",
      "regionName": "Hallands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Birger Svenssons väg 18",
      "depotPostalCode": "432 40",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Varbergs kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Varbergs kommun från lokal depå (Birger Svenssons väg 18)."
    },
    {
      "citySlug": "ornskoldsvik",
      "cityName": "Örnsköldsvik",
      "kommunName": "Örnsköldsviks kommun",
      "regionSlug": "vasternorrlands-lan",
      "regionName": "Västernorrlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Sjögatan 15",
      "depotPostalCode": "891 60",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Örnsköldsviks kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Örnsköldsviks kommun från lokal depå (Sjögatan 15)."
    },
    {
      "citySlug": "landskrona",
      "cityName": "Landskrona",
      "kommunName": "Landskrona stad",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Varvsgatan 12",
      "depotPostalCode": "261 51",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Landskrona stad",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Landskrona stad från lokal depå (Varvsgatan 12)."
    },
    {
      "citySlug": "motala",
      "cityName": "Motala",
      "kommunName": "Motala kommun",
      "regionSlug": "ostergotlands-lan",
      "regionName": "Östergötlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Verkstadsvägen 29",
      "depotPostalCode": "591 46",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Motala kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Motala kommun från lokal depå (Verkstadsvägen 29)."
    },
    {
      "citySlug": "trelleborg",
      "cityName": "Trelleborg",
      "kommunName": "Trelleborgs kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hedvägen 84",
      "depotPostalCode": "231 66",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Trelleborgs kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Trelleborgs kommun från lokal depå (Hedvägen 84)."
    },
    {
      "citySlug": "lidkoping",
      "cityName": "Lidköping",
      "kommunName": "Lidköpings kommun",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Källaregatan 14",
      "depotPostalCode": "531 40",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Lidköpings kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Lidköpings kommun från lokal depå (Källaregatan 14)."
    },
    {
      "citySlug": "alingsas",
      "cityName": "Alingsås",
      "kommunName": "Alingsås kommun",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Tomasgårdsvägen 9",
      "depotPostalCode": "441 39",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Alingsås kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Alingsås kommun från lokal depå (Tomasgårdsvägen 9)."
    },
    {
      "citySlug": "sandviken",
      "cityName": "Sandviken",
      "kommunName": "Sandvikens kommun",
      "regionSlug": "gavleborgs-lan",
      "regionName": "Gävleborgs län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Sveavägen 32",
      "depotPostalCode": "811 40",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Sandvikens kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Sandvikens kommun från lokal depå (Sveavägen 32)."
    },
    {
      "citySlug": "angelholm",
      "cityName": "Ängelholm",
      "kommunName": "Ängelholms kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Metallgatan 17",
      "depotPostalCode": "262 72",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Ängelholms kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Ängelholms kommun från lokal depå (Metallgatan 17)."
    },
    {
      "citySlug": "kungsbacka",
      "cityName": "Kungsbacka",
      "kommunName": "Kungsbacka kommun",
      "regionSlug": "hallands-lan",
      "regionName": "Hallands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hantverksgatan 20",
      "depotPostalCode": "434 42",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Kungsbacka kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Kungsbacka kommun från lokal depå (Hantverksgatan 20)."
    },
    {
      "citySlug": "karlskoga",
      "cityName": "Karlskoga",
      "kommunName": "Karlskoga kommun",
      "regionSlug": "orebro-lan",
      "regionName": "Örebro län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Lerviksvägen 8",
      "depotPostalCode": "691 50",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Karlskoga kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Karlskoga kommun från lokal depå (Lerviksvägen 8)."
    },
    {
      "citySlug": "koping",
      "cityName": "Köping",
      "kommunName": "Köpings kommun",
      "regionSlug": "vastmanlands-lan",
      "regionName": "Västmanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Sjötullsvägen 11",
      "depotPostalCode": "731 36",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Köpings kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Köpings kommun från lokal depå (Sjötullsvägen 11)."
    },
    {
      "citySlug": "katrineholm",
      "cityName": "Katrineholm",
      "kommunName": "Katrineholms kommun",
      "regionSlug": "sodermanlands-lan",
      "regionName": "Södermanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Starrvägen 14",
      "depotPostalCode": "641 49",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Katrineholms kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Katrineholms kommun från lokal depå (Starrvägen 14)."
    },
    {
      "citySlug": "visby",
      "cityName": "Visby",
      "kommunName": "Region Gotland",
      "regionSlug": "gotlands-lan",
      "regionName": "Gotlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Skarphällsgatan 11",
      "depotPostalCode": "621 41",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Region Gotland",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Region Gotland från lokal depå (Skarphällsgatan 11)."
    },
    {
      "citySlug": "vanersborg",
      "cityName": "Vänersborg",
      "kommunName": "Vänersborgs kommun",
      "regionSlug": "vastra-gotalands-lan",
      "regionName": "Västra Götalands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Trestad Center 12",
      "depotPostalCode": "462 56",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Vänersborgs kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Vänersborgs kommun från lokal depå (Trestad Center 12)."
    },
    {
      "citySlug": "falkenberg",
      "cityName": "Falkenberg",
      "kommunName": "Falkenbergs kommun",
      "regionSlug": "hallands-lan",
      "regionName": "Hallands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kabelvägen 9",
      "depotPostalCode": "311 50",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Falkenbergs kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Falkenbergs kommun från lokal depå (Kabelvägen 9)."
    },
    {
      "citySlug": "hudiksvall",
      "cityName": "Hudiksvall",
      "kommunName": "Hudiksvalls kommun",
      "regionSlug": "gavleborgs-lan",
      "regionName": "Gävleborgs län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Håstaholmen 6",
      "depotPostalCode": "824 42",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Hudiksvalls kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Hudiksvalls kommun från lokal depå (Håstaholmen 6)."
    },
    {
      "citySlug": "vastervik",
      "cityName": "Västervik",
      "kommunName": "Västerviks kommun",
      "regionSlug": "kalmar-lan",
      "regionName": "Kalmar län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Lunnargatan 14",
      "depotPostalCode": "593 62",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Västerviks kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Västerviks kommun från lokal depå (Lunnargatan 14)."
    },
    {
      "citySlug": "enkoping",
      "cityName": "Enköping",
      "kommunName": "Enköpings kommun",
      "regionSlug": "uppsala-lan",
      "regionName": "Uppsala län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Gesällgatan 15",
      "depotPostalCode": "745 39",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Enköpings kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Enköpings kommun från lokal depå (Gesällgatan 15)."
    },
    {
      "citySlug": "pitea",
      "cityName": "Piteå",
      "kommunName": "Piteå kommun",
      "regionSlug": "norrbottens-lan",
      "regionName": "Norrbottens län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Fläktgatan 12",
      "depotPostalCode": "941 47",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Piteå kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Piteå kommun från lokal depå (Fläktgatan 12)."
    },
    {
      "citySlug": "hassleholm",
      "cityName": "Hässleholm",
      "kommunName": "Hässleholms kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Industrigatan 14",
      "depotPostalCode": "281 43",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Hässleholms kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Hässleholms kommun från lokal depå (Industrigatan 14)."
    },
    {
      "citySlug": "ystad",
      "cityName": "Ystad",
      "kommunName": "Ystads kommun",
      "regionSlug": "skane-lan",
      "regionName": "Skåne län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Aulingatan 8",
      "depotPostalCode": "271 39",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Ystads kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Ystads kommun från lokal depå (Aulingatan 8)."
    },
    {
      "citySlug": "kiruna",
      "cityName": "Kiruna",
      "kommunName": "Kiruna kommun",
      "regionSlug": "norrbottens-lan",
      "regionName": "Norrbottens län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Industrigatan 19",
      "depotPostalCode": "981 38",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Kiruna kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Kiruna kommun från lokal depå (Industrigatan 19)."
    },
    {
      "citySlug": "harnosand",
      "cityName": "Härnösand",
      "kommunName": "Härnösands kommun",
      "regionSlug": "vasternorrlands-lan",
      "regionName": "Västernorrlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Saltviksvägen 11",
      "depotPostalCode": "871 54",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Härnösands kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Härnösands kommun från lokal depå (Saltviksvägen 11)."
    },
    {
      "citySlug": "strangnas",
      "cityName": "Strängnäs",
      "kommunName": "Strängnäs kommun",
      "regionSlug": "sodermanlands-lan",
      "regionName": "Södermanlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Dammvägen 10",
      "depotPostalCode": "645 47",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Strängnäs kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Strängnäs kommun från lokal depå (Dammvägen 10)."
    },
    {
      "citySlug": "kristinehamn",
      "cityName": "Kristinehamn",
      "kommunName": "Kristinehamns kommun",
      "regionSlug": "varmlands-lan",
      "regionName": "Värmlands län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Annebergsgatan 7",
      "depotPostalCode": "681 30",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Kristinehamns kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Kristinehamns kommun från lokal depå (Annebergsgatan 7)."
    },
    {
      "citySlug": "varnamo",
      "cityName": "Värnamo",
      "kommunName": "Värnamo kommun",
      "regionSlug": "jonkopings-lan",
      "regionName": "Jönköpings län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Margretelundsvägen 12",
      "depotPostalCode": "331 34",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Värnamo kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Värnamo kommun från lokal depå (Margretelundsvägen 12)."
    },
    {
      "citySlug": "solna",
      "cityName": "Solna",
      "kommunName": "Solna stad",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Svetsarvägen 15",
      "depotPostalCode": "171 41",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Solna stad",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Solna stad från lokal depå (Svetsarvägen 15)."
    },
    {
      "citySlug": "nacka",
      "cityName": "Nacka",
      "kommunName": "Nacka kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Cylindervägen 18",
      "depotPostalCode": "131 42",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Nacka kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Nacka kommun från lokal depå (Cylindervägen 18)."
    },
    {
      "citySlug": "huddinge",
      "cityName": "Huddinge",
      "kommunName": "Huddinge kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Regulatorvägen 21",
      "depotPostalCode": "141 49",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Huddinge kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Huddinge kommun från lokal depå (Regulatorvägen 21)."
    },
    {
      "citySlug": "taby",
      "cityName": "Täby",
      "kommunName": "Täby kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Enhagsvägen 18",
      "depotPostalCode": "187 40",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Täby kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Täby kommun från lokal depå (Enhagsvägen 18)."
    },
    {
      "citySlug": "sollentuna",
      "cityName": "Sollentuna",
      "kommunName": "Sollentuna kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Kuskvägen 6",
      "depotPostalCode": "191 62",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Sollentuna kommun",
      "primaryInspector": "Johan Eklund",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Sollentuna kommun från lokal depå (Kuskvägen 6)."
    },
    {
      "citySlug": "haninge",
      "cityName": "Haninge",
      "kommunName": "Haninge kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Hantverkarvägen 25",
      "depotPostalCode": "136 44",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Haninge kommun",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Haninge kommun från lokal depå (Hantverkarvägen 25)."
    },
    {
      "citySlug": "jarfalla",
      "cityName": "Järfälla",
      "kommunName": "Järfälla kommun",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "90–120 minuter",
      "depotAddress": "Datavägen 14",
      "depotPostalCode": "175 43",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Järfälla kommun",
      "primaryInspector": "Karin Bergström",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Järfälla kommun från lokal depå (Datavägen 14)."
    }
  ]
}