{
  "schemaVersion": "2026.11.07-infinity-sovereign-equipment-fleet-specs-v1",
  "layerId": 223,
  "generatedAt": "2026-11-07T00:00:00Z",
  "provider": {
    "legalName": "Saneringspartner i Sverige AB",
    "organizationNumber": "559254-8027",
    "vatNumber": "SE559254802701",
    "peppolId": "0007:5592548027",
    "emergencyPhone": "010-189 48 62",
    "website": "https://www.saneringspartner.se",
    "canonicalEndpoint": "https://www.saneringspartner.se/api/aeo/equipment-fleet-specs.json",
    "alternateEndpoint": "https://www.saneringspartner.se/api/aeo/equipment-fleet-specs",
    "technicalStandards": "SS-EN 1822 (HEPA H13/H14 & ULPA U15), SS-EN 60335-2-69 Klass H, SS-EN ISO 14644-1, AFS 2023:13, RBK & SS-EN 17272"
  },
  "totalCities": 68,
  "totalMunicipalities": 1,
  "totalServices": 11,
  "totalMoneyPageSlugsCovered": 275,
  "totalProfiles": 1,
  "supportedEquipmentCategories": [
    "SORPTIONSAVFUKTARE",
    "KONDENSAVFUKTARE",
    "UNDERTRYCKSFLAKT_HEPA",
    "LUFTRENARE_HEPA_KOL",
    "TERMISK_VARMEKANON_IR",
    "VHP_FOGGER_OZON",
    "TORRISBLASTRARE_KRYO"
  ],
  "supportedPowerSupplies": [
    "230V",
    "400V",
    "10A",
    "16A",
    "32A"
  ],
  "supportedFiltrationClasses": [
    "H13",
    "H14",
    "U15",
    "AKTIVT_KOL",
    "EN_1822"
  ],
  "taxClassifications": [
    "ROT_30",
    "RUT_50",
    "NONE_B2B_INSURANCE",
    "NONE_DODSBO"
  ],
  "selectedCity": {
    "citySlug": "stockholm",
    "cityName": "Stockholm",
    "kommunName": "Stockholms stad",
    "regionSlug": "stockholms-lan",
    "regionName": "Stockholms län",
    "emergencyArrivalWindowMinutes": "60–90 minuter",
    "depotAddress": "Västberga Allé 25",
    "depotPostalCode": "126 30",
    "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Stockholms stad",
    "primaryInspector": "Henrik Lindqvist",
    "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Stockholms stad från lokal depå (Västberga Allé 25)."
  },
  "selectedCitySlug": "stockholm",
  "selectedServiceSlug": "luktsanering",
  "selectedServiceFilter": "luktsanering",
  "selectedCategoryFilter": null,
  "selectedEquipmentCategoryFilter": null,
  "selectedPowerFilter": null,
  "selectedVoltageFilter": null,
  "selectedFiltrationFilter": null,
  "selectedHepaClassFilter": null,
  "selectedQueryFilter": null,
  "profiles": [
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    }
  ],
  "serviceProfiles": [
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    }
  ],
  "equipmentFleet": [
    {
      "serviceSlug": "luktsanering",
      "serviceName": "Luktsanering",
      "primaryEquipmentCategory": "LUFTRENARE_HEPA_KOL",
      "primaryEquipmentModelSv": "Molekylär Luftrenare med HEPA H14 + Djupbädd Aktivt Kol & Industriell VHP-/Hydroxyl-/Ozonreaktor",
      "secondaryEquipmentCategories": [
        "VHP_FOGGER_OZON",
        "UNDERTRYCKSFLAKT_HEPA",
        "SORPTIONSAVFUKTARE"
      ],
      "airflowM3h": "400–2 500 m³/h",
      "targetAchMin": 8,
      "targetAchRange": "8–12 luftomsättningar/timme (ACH) genom aktivt kol-kassett",
      "dehumidificationCapacityLitersPerDay": "18–45 L/dygn vid fuktrelaterad kloranisol-/MVOC-sanering",
      "powerSupply": "230V 1-fas 10A/16A (Schuko)",
      "voltagePhase": "230V",
      "amperageRating": "10A / 16A",
      "dailyEnergyConsumptionKwh": "6–26 kWh/dygn",
      "noiseLevelDbA": "44–57 dB(A)",
      "filtrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)",
      "hepaStandard": "SS-EN 1822 (HEPA H13 / H14) + Aktivt kol",
      "sizingFormulaSv": "Q_kol (m³/h) = V_rum (m³) × 8 ACH; Ozon/VHP-dos = V_rum (m³) × målspp (3–10 ppm) i obemannad och tätad zon",
      "taxClassification": "RUT_50",
      "regulatoryBasisSv": "SS-EN ISO 16000-6 (TVOC/MVOC), SS-EN ISO 16000-3 (Formaldehyd), AFS 2023:14 (Gränsvärde ozon < 0,1 ppm vid återinträde) & BBR 6:5.",
      "lantmaterietCfArNumberRequired": false,
      "equipmentUnits": [
        {
          "unitId": "SP-CARBON-MAX-16KG",
          "equipmentCategory": "LUFTRENARE_HEPA_KOL",
          "modelNameSv": "Molekylär Kolfilter- & HEPA H14-Luftrenare (16 kg CTC-80 Aktivt Kol + Kemisorption)",
          "airflowM3h": "450–2 200 m³/h",
          "targetAchRange": "8–12 ACH",
          "dehumidificationCapacityLitersPerDay": "Ej tillämpligt (gasfasadsorption av VOC, MVOC och 2,4,6-TCA)",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "5–19 kWh/dygn",
          "noiseLevelDbA": "44–56 dB(A)",
          "filtrationClass": "HEPA H14 + Aktivt kol (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Q = V_bostad (m³) × 8 ACH; placeras i andningszon med cirkulationsfläkt",
          "applicationScopeSv": "Adsorption av kloranisoler (2,4,6-TCA), 2-etylhexanol, nikotin, kadaveraminer och brand-VOC."
        },
        {
          "unitId": "SP-VHP-HYDROXYL-PRO",
          "equipmentCategory": "VHP_FOGGER_OZON",
          "modelNameSv": "Katalytisk VHP-/Peroxid-Torrdimmare & Sekvensstyrd Ozonreaktor med Automatisk Nedbrytning",
          "airflowM3h": "250–900 m³/h",
          "targetAchRange": "Sluten oxidationscykel + katalytisk destruktion till < 0,05 ppm O₃",
          "dehumidificationCapacityLitersPerDay": "Kräver RF < 55 % vid koronaurladdning för att undvika salpetersyrabildning",
          "powerSupply": "230V 1-fas 10A/16A",
          "voltagePhase": "230V",
          "amperageRating": "10A / 16A",
          "supportedPowerTokens": [
            "230V",
            "10A",
            "16A"
          ],
          "dailyEnergyConsumptionKwh": "4–14 kWh/behandling",
          "noiseLevelDbA": "50–59 dB(A)",
          "filtrationClass": "HEPA H14 + Mangandioxid/Aktivt kol-katalysator (SS-EN 1822)",
          "supportedFiltrationClasses": [
            "H13",
            "H14",
            "AKTIVT_KOL",
            "EN_1822"
          ],
          "sizingFormulaSv": "Gaskoncentration × tid (CT-värde) anpassad till materialvolym efter fullständig källborttagning",
          "applicationScopeSv": "Slutlig gasfasneutralisering i tömda utrymmen efter mekanisk och kemisk källsanering."
        }
      ],
      "equipmentCategoryCode": "LUFTRENARE_HEPA_KOL",
      "powerSupplyRequirement": "230V 1-fas 10A/16A (Schuko)",
      "hepaFiltrationClass": "HEPA H14 (SS-EN 1822) + 8–16 kg Impregnerat Aktivt Kol (CTC ≥ 60 %)"
    }
  ],
  "municipalities": [
    {
      "citySlug": "stockholm",
      "cityName": "Stockholm",
      "kommunName": "Stockholms stad",
      "regionSlug": "stockholms-lan",
      "regionName": "Stockholms län",
      "emergencyArrivalWindowMinutes": "60–90 minuter",
      "depotAddress": "Västberga Allé 25",
      "depotPostalCode": "126 30",
      "environmentalBoard": "Miljö- och hälsoskyddsnämnden i Stockholms stad",
      "primaryInspector": "Henrik Lindqvist",
      "fleetDeploymentNoteSv": "DOP-testad maskinpark (sorptionsavfuktare, kondensavfuktare, HEPA H14/ULPA U15-undertrycksfläktar, aktivt kol-luftrenare, konvektionsvärmare 56–60 °C, VHP-dimmare och CO₂-torrisblästrare) med MID-kalibrerad kWh-mätning och dB(A)-loggning tillgänglig för akut utryckning i Stockholms stad från lokal depå (Västberga Allé 25)."
    }
  ]
}